CFM UVHK29MN Manuale Utente

Pagina di 20
4
20008056
The National Fuel Gas Code, ANSI Z223.1/NFPA 54 
defines a confined space as a space whose volume 
is less than 50 cubic feet per 1,000 Btu per hour 
(4.8m
3
 per kw) of the aggregate input rating of all 
appliances installed in that space and an unconfined 
space as a space whose volume is not less than 50 
cubic feet per 1,000 Btu per hour (4.8 m
3
 per kw) of 
the aggregate input rating of all appliances installed 
in that space.  Rooms communicating directly with 
the space in which the appliances are installed, 
through openings not furnished with doors, are con-
sidered a part of the unconfined space.
WARNING:  During manufacturing, fabricating and 
shipping, various components of this appliance are 
treated with certain oils, films or bonding agents.  
These chemicals are not harmful but may produce 
annoying smoke and smells as they are burned off 
during the initial operation of the appliance, possibly 
causing headaches and eye/lung irritation.  This is a 
normal and temporary occurrence.
Important Safeguards
Although your gas logs are very realistic in appearance, 
it is not a real wood-burning fireplace and must not be 
used for burning rejected material.
To avoid irreparable damage to the appliance or personal in-
jury; matches, paper, garbage or any other material must not 
be placed or thrown on top of the logs or into the flames.
To avoid personal injury, do not touch hot surfaces when 
the appliance is operating.
Touch only the piezo button and control knob. Avoid contact 
with the front screen, canopy or any other part which will be 
very hot.
Always ensure that the fireplace screen is in place when 
the appliance is operating and, unless other provisions 
for combustion air are provided, the screen shall have 
opening(s) for introduction of combustion air.
Close supervision is necessary when the appliance is be-
ing operated near children.
Do not use to cook food.
If this is the ONLY gas appliance, we recommend a minimum 
200 pound cylinder with a fill gauge.  Use of a 100 pound 
cylinder is not recommended.  Other household gas appli-
ances may require the tank size to be larger.  Do not operate 
the vent free fireplace if the fuel level in the propane tank is 
below 1/4 full.
WARNING: The glowing ember base and all the 
logs are manufactured from bonded ceramic 
fiber. This is a commonly used material in indus-
try worldwide. In the event of the logs and base 
being removed, care should be taken not to dam-
age the bonded material.
Intentional misuse of, or deliberately fragment-
ing, the material could lead to inhaling fibers and 
be injurious to health.
This appliance is intended to be used only for supplemental 
heat.  Do not use it routinely as a primary heat source.  
Continuous operation could produce excessive humidity de-
pending on construction characteristics and outdoor tempera-
tures (below 20°F).  Over time, this could cause condensation 
to form and damage wall structures and exterior paint.
WARNING:  Failure to keep primary air 
opening(s) of the burner(s) clean may result in 
sooting and property damage.
WARNING:  If the area in which the heater may 
be operated is smaller than that defined as an 
unconfined space or if the building is of unusu-
ally tight construction, provide adequate com-
bustion and ventilation air by one of the methods 
described in the National Fuel Gas code, ANSI 
Z223.1/NFPA 54, Section 5.3, (or applicable local 
codes).