Dutchwest Natural Vent Gas Heater
30002008
 
Conversion to LP 
Input (BTU/h) 
Air Shutter
 
Kit # 
Front 
Part # 
Rear 
Part # 
Minimum  Maximum 
Setting
  000-5022  #69 / .029”  30000513  #54 / .055”  20000130 
21,500 
28,000 
3/8” Open
 
Conversion to Natural Gas 
Input (BTU/h) 
Air Shutter
 
Kit # 
Front 
Part # 
Rear 
Part # 
Minimum  Maximum 
Setting
  000-5021  #54 / .055”   20000130  #44 / .086”  30000334 
19,000 
28,000 
Fully Closed
Table 2.  Injector Orifice Size Matrix