England's Stove Works 26-GUHNG Manuale Utente

Pagina di 13
GAS RATINGS 
 
TYPE OF GAS       
                  NATURAL  
 
L.P./PROPANE 
 
MAX. INPUT 
 
 
     34,500 BTU/HR 
 
30,000 BTU/HR 
MIN. INPUT 
 
 
     20,000 BTU/HR 
 
20,000 BTU/HR 
MANIFOLD PRESSURE 
     3.5” W.C. 
 
 
10” W.C. 
M/FOLD PRESSURE LOW 
     1.0/3.5” W.C. 
 
4.5/10.0” W.C. 
MIN. INLET PRESSURE 
     5.0” W.C. 
 
 
11.0” W.C. 
MIN. SUPPLY PRESSURE 
     5.5” W.C. 
 
 
11” W.C. 
MAX. SUPPLY PRESSURE 
     10.5” W.C.   
 
14” W.C. 
ORIFICE SIZE   
 
     #34   
 
 
#51 
 
 
MINIMUM CLEARANCES TO COMBUSTIBLES 
 
 
 
THIS APPLIANCE SHALL BE INSTALLED ON A METAL OR WOOD PANEL THAT 
EXTENDS THE FULL WIDTH AND DEPTH OF THE APPLIANCE WHEN INSTALLED 
ON A COMBUSTIBLE SURFACE OTHER THAN WOOD. 
 
 
 
WARNING: WHEN USED WITHOUT FRESH AIR THIS HEATER MAY GIVE OFF 
CARBON MONOXIDE, AN ODORLESS POISONOUS GAS. 
 
 
 
OPEN A WINDOW AN INCH OR TWO FOR COMBUSTION AIR. 
 
 
 
 
England’s Stove Works highly recommends the use of smoke detectors and 
Carbon Monoxide detectors with any hearth product, including this unit.  Follow all 
manufacturer’s instructions when using smoke or Carbon Monoxide detectors.