Honeywell HE220 Manuale Utente

Pagina di 24
HE220, HE260 HUMIDIFIER AND INSTALLATION KIT
69-1645EF
8
MAINTAINING YOUR HUMIDIFIER
A regular maintenance program prolongs the life of your 
humidifier and makes your home more comfortable. The 
frequency of cleaning depends on the condition of your 
water. 
You can use either hard or soft water in your humidifier, 
but hard water mineral deposits are more difficult to clean 
than soft water deposits. 
Use the following procedure to clean your Honeywell 
humidifier.
WARNING
Serious Personal Injury Hazard. 
Can cause electrical shock and injury from 
moving parts.
Disconnect power and shut off water supply 
before removing cover.
IMPORTANT
Never oil any part of the humidifier.
Every 1 to 3 Months (Depending on Water 
Quality)
1.
Disconnect the power and turn off the humidifier 
water supply.
2.
Remove the humidifier cover. See Fig. 16.
3.
Remove the humidifier pad assembly from the 
humidifier by grasping the top of the tray and pull-
ing it toward you.
4.
Pull one side of the humidifier pad assembly frame 
toward you and remove the tray from the frame.
5.
Gently pinch the water nozzle catches inward until 
you can lift the water nozzle off the tray.
6.
Slide the humidifier pad out of the frame.
7.
Carefully remove any mineral deposits from the 
tray and frame. Be sure the frame drain hole has 
nothing blocking it.
8.
Disconnect the drain hose from the drain fitting on 
the bottom of the humidifier housing.
9.
Clean the drain fitting, if necessary.
10.
Bend the drain hose to loosen any mineral depos-
its.
11.
Flush the drain hose with pressurized water (a run-
ning tap) to clean the hose.
12.
Reattach the drain hose to the drain fitting.
13.
Slide the humidifier pad back into the frame.
14.
Snap the water nozzle back on the tray.
15.
Reattach the tray to the frame.
16.
Place the humidifier pad assembly in the humidifier 
housing and press until the assembly is completely 
seated. Be careful not to pinch or kink the water 
feed tube. 
17.
Replace the humidifier cover.
18.
Verify the humidifier operation by following the 
steps in the Checking Your Humidifier for Correct 
Operation section.
End of Humidification Season
Clean the humidifier and shut it off at the end of the 
heating season. 
Use Every 1 to 3 Months section steps to shut down 
for the season.
IMPORTANT
Be sure the humidifier power is off.
Vacation 
When leaving on vacation, turn off the humidifier 
water supply and your humidistat. 
When you return, turn on the humidifier water supply  
and reset your humidistat.
Fig. 16. Cleaning your humidifier.
CHECKING YOUR HUMIDIFIER FOR 
CORRECT OPERATION
After winter startup or servicing, use the following steps 
to check your humidifier operation:
1.
Turn on the humidifier power and water supply.
2.
Turn the humidistat to its highest setting and set 
the thermostat to 10°F (6°C) above the room tem-
perature.
3.
Observe that water is flowing out of the drain hose.
NOTE:
The furnace blower must be running to activate 
the humidifier.
4.
Reset the thermostat and humidistat to a comfort-
able setting for automatic operation.
M12327A
PerfectFlo™ WATER
DISTRIBUTION TRAY
HUMIDIFIER PAD ASSEMBLY
WATER FEED NOZZLE
HUMIDIFIER HOUSING
SIDEWALL
BYPASS SIDEWALL
COVER
WATER FEED TUBE