PRODUCT MODEL NUMBERS
NGD7300W
Gas supply
This dryer is equipped for use with Natural 
gas. Dryer can be converted to L.P. gas. When rigid 
pipe is used it should be 1/2" IPS. When acceptable  
to the gas supplier and local codes, 3/8" approved  
tubing may be used for lengths under 20 ft (6.1 m).  
For lengths over 20 ft (6.1 m), larger tubing should be 
used. Pipe-joint compounds resistant to the action of 
L.P. gas must be used. An individual manual shutoff 
valve must be installed within 6 ft (1.8 m) of the dryer 
in accordance with the National Fuel Gas Code ANSI 
Z223.1. 
 
Electrical
A 120-volt, 60 Hz, AC-only, 15 or 20 amp 
fused electrical supply is required. A time-delay fuse or 
circuit breaker and a separate circuit are recommended. 
 
Water
 
(Steam models only)
The dryer must be  
connected to the cold water faucet using new inlet 
hoses. Do not use old hoses. Do not overtighten.  
Damage to the coupling can result.
   
4"
(102 mm)
2½"
(64 mm)
     
4"
(102 mm)
      
4"
(102 mm)
B
A
A. Louvered hood  
B. Box hood 
C. Angled hood (acceptable) 
C
Because Whirlpool Corporation policy includes a continuous commitment to improve 
Dimensions are for planning purposes only. For complete details, see Installation 
our products, we reserve the right to change materials and specifications without notice. 
Instructions packed with product. Specifications subject to change without notice.
Ref. W10240584C 
11/2010
OVERALL DIMENSIONS
Dryer dimensions
Select the route that will provide the straightest and most 
direct path outdoors. Plan the installation to use the fewest 
number of elbows and turns. Use the fewest 90° turns 
possible.
Do not use vent runs longer than specified in vent length 
chart.
Determine the number of elbows you will need.
For closet installation, with a door, the minimum ventilation openings in the top 
and bottom of the door are required. Louvered doors with equivalent air ventilation 
openings are acceptable.
Exhaust venting
Exhaust your dryer to the outside. 
4" (102 mm) diameter vent is required. Rigid or flexible 
metal exhaust vent must be used. Do not use plastic  
or metal foil vet. Exhaust hood must be at least  
12" (305 mm) from the ground or any object that  
may be in the path of the exhaust.
Hood styles: A & B are recommended.
The vent system chart provides venting requirments 
that will help to achieve the best drying performance.
Vent system chart:
  
NOTE: Side and bottom exhaust installations have  
a 90° turn inside the dryer. To determine maximum  
exhaust length, add one 90° turn to the chart.
Cabinet and closet dimensions 
6
1
/
4
"
(159 mm)
28
1
/
8
"
(715 mm)
3
1
/
2
"
(89 mm)
14"
(358 mm)
Electric
Front view
Side view
Back view
Stacked washer and 
 dryer installation
Closet (dryer only) installation
Cabinet (dryer only) installation
Custom under counter (dryer only) 
installation
Number of 
90  turns 
or elbows
Type of
vent
Box or 
Louvered 
hoods
Angled
hoods
0
Rigid metal
64 ft (20 m)
58 ft (17.7 m)
1
54 ft (16.5 m) 
48 ft (14.6 m)
2
44 ft (13.4 m)
38 ft (11.6 m)
3
35 ft (10.7 m)
29 ft (8.8 m)
4
27 ft (8.2 m)
21 ft (6.4 m)
Rigid metal
Rigid metal
Rigid metal
Rigid metal
o
27"
(686 mm)
1"
(25 mm)
35
3
/
8
"
(899 mm)
3
1
/
2
"
(89 mm)
29"
(736 mm)
Left or
 
right side 
exhaust
6
7
/
8
"
(174 mm)
1
5
/
8
"
(41 mm)
47
1
/
8
"
(1197 mm)
48
1
/
8
"
(1238 mm)
Door Open view
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
1"
(25 mm)
1"
(25 mm)
4"
(102 mm)
3"
(76 mm)
34" recommended
(864 mm)
18" min.
(457 mm)
3"
(76 mm)
1"
(25 mm)
1"
(25 mm)
4"
(102 mm)
7"
(178 mm)
18"
(460 mm)
1"
(25 mm)
1"
(25 mm)
39" min.
(990 mm)
1"
(25 mm)
1"
(25 mm)
5
1
/
2
"
(140 mm)
24 in.
2
(155 cm
2
)
48 in.
2
(310 cm
2
)
3"
(76 mm)
3"
(76 mm)
6"
(152 mm)
76"
(1930 mm)