ERIFICATION
Verification without an Upstream Device
Verify that the H2TU-R powers up. The following should occur:
The front-panel ALM LED is a steady red. 
The LOOP LED is flashing green.
If receiving a DS1 signal, one of the DS1 framing LEDs (ESF or SF) and one of the DS1 line code LEDs 
(B8ZS or AMI) is a steady green. 
Verification with an Upstream Device
1
Verify that the H2TU-R powers up. 
The front-panel ALM LED is a steady red. 
The LOOP LED is flashing green.
If receiving a DS1 signal, one of the DS1 framing LEDs (ESF or SF) and one of the DS1 line code LEDs 
(B8ZS or AMI) is a steady green.
2
Verify that the H2TU-R attempts to communicate with an upstream device (LOOP LED is flashing green). 
One of the following occurs:
If an upstream device is successfully identified and the HDSL2 loop synchronizes, the LOOP LED lights 
a steady green.
If upstream devices are not successfully identified, the H2TU-R continues to attempt communication 
(LOOP LED flashes green) until an upstream device is detected.