ADC Remote Manuale Utente

Pagina di 46
Loopback Operation
 
 152-402-145-02, Issue 2
30
June 16, 2000
 H2TU-R-402
A3LB and A4LB Test Procedures
The H2TU-C can be looped back by sending the Addressable Office Repeater (AOR) LPBK activation code 
1111-1111-0001-1110 (FF1E) for at least 5 seconds. This causes the H2TU-R-402 to enter the NLOC state. The 
H2TU-C Loopback Time-out (LBTO) setting determines the duration of this loopback unless it is overridden by 
the reception of a second identical 16-bit loopup command before the timer expires. When this time-out override 
state exists, the only way to loop the H2TU-R-402 down is to issue one of the three loopdown commands listed 
in 
. The automatic time-out mode is restored during subsequent loopback sessions.
 summarizes the codes required to execute Addressable 3 (A3LB) and Addressable 4 (A4LB) repeater 
loopback commands. All code sequences must be present for at least 5 seconds.
Table 12.
Addressable Repeater Loopback Commands (A3LB and A4LB)
Name
Description
Binary Code
 (a)
 (Hexadecimal Equivalent)
(a) The leftmost bit arrives first in all sequences. The detection algorithm functions reliably with a random 10
-3
 Bit Error Ratio (BER) 
on the facility. The entire arming and loopback sequence can also be initiated at the remote H2TU-R location.
NLOC
H2TU-R-402 loopup from NI
1111-1111-0001-1110 (FF1E)
CREM
H2TU-R-402 loopup from CI 
0011-1111-0001-1110 (3F1E)
NREM
H2TU-R loopup from NI
1111-1111-0000-0010 (FF02)
CLOC
H2TU-R loopup from CI
0011-1111-0000-0010 (3F02)
SMJK
H2TU-R loopup from NI
11000-11000-11000 ...
SMJK
H2TU-R loopup from NI
 (b)
(b) Not supported by A4LB.
100000 100000 100000 ...
SMJK
H2TU-R loopup from NI (ESF-DL)
1111-1111-0100-1000 (FF48)
Loopdown
H2TU-C and H2TU-R loopdown from NI OR CI
11100-11100-11100 ...
Loopdown
H2TU-C and H2TU-R loopdown from NI OR CI
100-100-100 ...
Loopdown
H2TU-C and H2TU-R loopdown from NI OR CI (ESF-DL)
1111-1111-0010-0100 (FF24)