Installation to a concrete wall
Drill two 1/4" (6 mm) dia. holes to a minimum depth of
2.5" (64 mm). Attach support arm (A) using concrete
anchors
(call customer service to order accessory kit ACC
200 or ACC203)
 and #14 x 2.5" wood screws (F) as
shown in Illustration A and 12, and 3. Tighten all
fasteners.
1
3
Drill hole and insert anchor
Place wall plate over anchor and secure with screw
After repeating step one tighten all fasteners
CUT
A
W
A
Y
 VIEW
INCORRECT
concrete
metal
bracket
plaster/
dry wall
CORRECT
concrete
metal
bracket
plaster/
dry wall
concrete
wall
concrete
anchor
concrete
anchor
concrete
anchor
F
F
2
A
WARNING
• When installing Peerless wall mounts on cinder block, verify that you have a minimum of 1-3/8" of actual concrete
surface in the hole to be used for the concrete anchors. Do not drill into mortar joints! Be sure to mount in a solid
part of the block, generally 1" minimum from the side of the block. Cinder block must meet ASTM C-90 specifica-
tions. It is suggested that a standard electric drill on slow setting is used to drill the hole instead of a hammer drill
to avoid breaking out the back of the hole when entering a void or cavity.
• Concrete must be 2000 psi density minimum. Lighter density concrete may not hold concrete anchor.
• Make sure that the wall will safely support four times the combined load of the equipment and all attached hard-
ware and components.
• Tighten wood screws firmly, but do not overtighten.
Overtightening can damage the screws, greatly
reducing their holding power.
• Never tighten in excess of 80 in • lb (9 N.M.).
WARNING
• Concrete anchors are not intended for attachment to
concrete wall covered with a layer of plaster, drywall,
or other finishing material. If mounting to concrete wall
covered with plaster/drywall is unavoidable, plaster/
drywall (up to 5/8" thick) must be counterbored as
shown right. If plaster/drywall is thicker than 5/8",
custom fasteners must be supplied by installer.
WARNING
concrete
anchor
F
A
Illustration A