4 Administrator Settings 
101 
PRI Red Alarm 
 
Red alarm or Loss of signal (LOS) means that there is no signal and thus no framing info 
received (this has same effect as pulling out the PRI cable). 
 
PRI Yellow Alarm 
 
Yellow alarm or Remote Alarm Indicator (RAI) means that the system is receiving framing 
info, but in this framing info the other side tells the system that it is not reading the system
transmitted framing info. Typically, this may be a broken connector in the TX part of the 
system PRI cable. This could also indicate weak or noisy signal in the TX part of the system 
PRI cable. 
 
PRI Blue Alarm 
 
Blue alarm means that network on the far side of the CSU is unavailable. 
 
 
Example:  
 
The system is connected via a CSU (i.e. a NT 
Network Termination
) as follows: 
System
cableA
CSU
cableB
Network 
 
If a CSU loses framing/sync from the network (example: a bad cable B), it shall no 
longer send valid framing out on cable A towards the system. Instead it transmits "Blue 
Alarm". Seen from a system receiving blue alarm, this means that the network on the 
far side of the CSU is unavailable. 
 
 
 
4.9.4   System Selftest 
 
 
The system performs a check to determine internal hardware integrity. System Selftest is 
useful when you want to check if your network connection is active. 
 
4.9.5   View Administrator Settings 
 
 
This window displays all the system settings. Use the arrow key on the remote control to 
scroll through the list. 
 
View Administrator Settings contain: 
 
General Settings 
System Name  
Language  
Dual Monitor  
Auto answer  
Max Call Length  
Access Code  
Incoming MCU calls  
Incoming Telephone calls