Aiphone JK-1MD Manuale Utente

Pagina di 12
- 3 -
English
Fr
ançais
Español
Neder
lands
Italiano
  2 
INSTALLATION
2-1 Mounting locations
1
  Install the master monitor station in a place 
where the screen is not exposed to direct 
sunlight.
2
  The master monitor station has switches on 
both sides. Allow at least 5 cm (2") of open 
space on either side.
3
  Allow 15 cm (6") or more of vertical open 
space from the center of the mounting 
bracket in order to mount the master 
monitor station.
+ 5 cm
(2")
+ 5 cm
(2")
JK-1MD / JK-1HD
2
3
+ 15 cm
(6")
2-2 Wiring method, wiring distance
Wire the units from station-to-station (daisy-chained).
Ø 0.65 mm
22 AWG
Ø 1.0 mm
18 AWG
A
50 m
165'
100 m
330'
B
5 m
16'
10 m
33'
C
75 m
245'
150 m
490'
JK-1HD
JK-1SD
JK-1MD
JK-DA
JK-DV
JK-DVF
2
4
PS18
PS-1820
PS-1810DIN
PS-1820DIN
A
B
C
IER-2
2-3 Cable
1
  Use PVC-coated cable with PE (polyethylene) insulation.
(x2)
2
  Never use individual conductors, twisted pair cable or coaxial cable. 
3
  When using a cable with unused conductors, terminate both ends of 
the unused pair(s) with a 120 
Ω resistor.
JK-1MD
JK-1HD/JK-1SD
120
120
+
-
A1
A2
B1
B2
L
L
S
S
+
-
SW
SW
B1