Aiphone A83090 Dépliant

Pagina di 2
- 2 -
Printed in Japan (E)
AIPHONE CO., LTD., NAGOYA, JAPAN
AIPHONE CORPORATION, BELLEVUE, WA, USA
AIPHONE EUROPE N.V., ANTWERP, BELGIUM
NE-JA-I (E) 1201A
WARRANTY
Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period 
of one year after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective 
upon which examination shall disclose to be defective and under warranty.  Aiphone reserves unto itself the sole right to make 
the final decision whether there is a defect in materials and/or workmanship; and whether or not the product is within the 
warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation 
of instructions furnished, nor extended to units which have been repaired or altered outside of the factory.  
This warranty does not cover batteries or damage caused by batteries used in connection with the unit.
This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone. 
Aiphone will not be responsible for any costs incurred involving on site service calls.
WIRING DIAGRAM
OPARATION
TECHNICAL PRECAUTIONS
SPECIFICATIONS
NE-JA
NE-JA
(w/dry closure 
output)
NE-JA
(w/corridor 
lamp)
NEM master
(NEM-40A/C)
Dry closure output
for duration of call-in
: PS-24E. PS-2410A (USA. for up to 20 subs)
NBY-4A
Do not apply any caulking seals around 
sub station.  Water drainage holes on 
bottom will help water or moisture to 
dissipate.
Clean NE-JA with a soft cloth dampened 
with neutral household cleaner and cloth.  
Do not spray high-pressure water on sub 
station.
Caulking seals:
Cleaning:
Power Source:
Speaker:
Call Annunciation:
Communication:
Mounting:
Wiring:
         In USA only; 
Wiring Distance:
1
2
40
E
+
-
H
1
2
RY-PA
1
2
3
4
10 (1/2")
116 (4-1/2")
115 (4-1/2")
NOTES:
1. The NE-JA can have the external closure 
option, the corrindor lamp, or both 
connected.
2. When including a corridor lamp, cut 
GRN/BLK jumper, and connect NBY-4A to  
terminals 2 and 3 on sub station. 
3. When using the extra contact, connect 
input (coil) of relay to H of master and 
terminal 4 at sub.
4. The dry closure will stay activated from the 
time the call is placed until it is answered 
at the master station. The RY-PA is a 12V 
DC, "normally open" relay. If a "normally 
closed" contact is required, the RY-PA can 
be changed to N/C, or a standard 12V DC, 
N/C relay can be used.
GRN/BLK
jumper
TERMINAL DEFINITIONS:
1, 2: Call-in and communication
  3:   Corridor lamp activation
  4:   External relay activation
Cut the jumper 
when corridor 
lamp is installed 
at sub. Secure 
insulation.
Blk
Blk
Yel
(2)
Blu
Blu
Blu
Blu
1. To place a call, press call button on door station once. The 
call-in tone and LED will be lit on the master station, 
remaining activated until answered. The LED on the door 
station will be lit to indicate a call has been placed.
2. When the master station answers, a brief pretone will be 
heard. Speak into the door station hands free.
3. When the call is completed, the person at the master will 
press OFF button, and communication will be cut off. The 
person at the remote station does nothing.
4. If a corridor lamp is included, the lamp will be lit from the 
time the call is placed until answered.
5. If a relay is included at the remote station to provide an 
extra dry closure, the closure will be activated from the 
time the call is placed until answered. 
Supplied by master station
20 ohms
Pressing call button at remote latches 
call at NEM master until answered.
Hands free at sub. Master is push-to-talk 
or VOX handset.
NE-JA flush mounts in 2-gang electrical 
box with stainless steel cover over unit.
2 conductors homerun; or 1 common plus 1 
individual per sub, looped through each sub. 
Shielded cable is recommended.
Use Aiphone #822202 or #821802 for 
homerun wiring, #822206 for up to 5 
stations on each run, or #822210 for up to 
9 stations on each run.
Dimensions:
 (H x W x D; mm)
115(4-1/2") x 116(4-1/2") x 10(1/2") (outer depth)
RY-PA
Coil Rating:
Contact Rating:
12V DC, supplied by H terminal of master
110V AC, 1A, or up to 24V DC, 1A
Diameter 0.65mmø 1.0mmø
AWG
22AWG 18AWG
Distance
110m
270m
Distance
360'
880'
2 wires homerun
Diameter 0.65mmø 1.0mmø
AWG
22AWG 18AWG
Distance
70m
170m
Distance
230'
560'
1 wire common +1 per sub 
(applicable for max. two NE-JA's)
NAR-2A
Homerun wiring of NE-JA's
PS24
PS24
1
2
3
4