Honeywell HRDP DVR Manuale Utente

Pagina di 90
Installation 
 
______________________________________________________________________________________________ 
24 
 
Connecting a PTZ Camera 
 
The RS485 connector can be used to control Pan / Tilt / Zoom 
(PTZ) cameras. See the PTZ camera manufacturer’s manual 
for configuring the RS485 connection. 
Note 
Use the RS485 connector for external control 
systems such as a control keyboard. Connect  
RX-/TX- and RX+/TX+ of the control system to the 
TX-/RX- and TX+/RX+ (respectively) of the DVR. 
 
 
Connecting to a Sensor Input 
 
To make connections on the Alarm Connector Strip, press and hold the button 
and insert the wire into the hole above the button. To disconnect the wire press 
and hold the button below the wire and pull out 
 Alarm 
In 
 
 
Use external devices to send a signal 
to the DVR when an event occurs. 
Mechanical or electrical switches can 
be wired to the Alarm In and Ground 
(GND) connectors. 
 
Note 
All connectors marked GND are common. Connect the ground side 
of the alarm input and/or alarm output to the GND connector. 
Connecting to a Relay Output 
 
To make connections on the Alarm Connector Strip, press and hold the button 
and insert the wire into the hole above the button. To disconnect the wire press 
and hold the button below the wire and pull out. 
 Alarm 
Out 
 
 
The DVR can activate external 
devices such as buzzers or lights. 
Connect the external device to the 
Alarm Out and Ground (GND) 
connectors. See Sensor 
Configuration in the manual for more 
details.