4.10.4 I/O Control
Figure 4-36 is a screenshot of the I/O Control Setting Menu. This menu is used to define the settings for
controlling the DVR through RS485, and for DVR control of attached PTZ cameras.
controlling the DVR through RS485, and for DVR control of attached PTZ cameras.
Figure 4-36 System Menu – I/O Control
RS232
Baud Rate: This field is to set the speed at which is used to transmit instruction or information through the
RS232 port on the DVR. There are eight different speeds: 1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS,
19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS.
Data Bit: This field is the data bit at which you will be transferring. There are two settings for this option: 8
Data Bit: This field is the data bit at which you will be transferring. There are two settings for this option: 8
or 7.
Stop Bit: This field is to set the stop bit for the RS232 connection. There are two different stop bits, 1 or 2.
Parity: This field is to select the parity level at which you will be connected. You can choose between None,
Odd, or Even parity levels.
Stop Bit: This field is to set the stop bit for the RS232 connection. There are two different stop bits, 1 or 2.
Parity: This field is to select the parity level at which you will be connected. You can choose between None,
Odd, or Even parity levels.
RS485
PTZ Protocol: Select PTZ protocol, choose from the following protocols: Transparent, Pelco D, Pelco P,
Everfocus, or Samsung. (NOTE: all cameras on the bus must use the same protocol)
485 ID: This is the ID used by the EKB500 to send commands to the DVR. On an RS485 connection, every