4.10.4 I/O Control  
Figure 4-36 is a screenshot of the I/O Control Setting Menu. This menu is used to define the settings for 
controlling the DVR through RS485, and for DVR control of attached PTZ cameras. 
 
Figure 4-36 System Menu – I/O Control 
 
RS232 
Baud Rate:
 This field is to set the speed at which is used to transmit instruction or information through the 
RS232 port on the DVR. There are eight different speeds: 1200 BPS, 2400 BPS, 4800 BPS, 9600 BPS, 
19200 BPS, 38400 BPS, 57600 BPS and 115200 BPS. 
Data Bit: This field is the data bit at which you will be transferring. There are two settings for this option: 8 
or 7. 
Stop Bit: This field is to set the stop bit for the RS232 connection. There are two different stop bits, 1 or 2. 
Parity: This field is to select the parity level at which you will be connected. You can choose between None, 
Odd, or Even parity levels.
 
 
 
RS485 
PTZ Protocol:
 Select PTZ protocol,  choose from the following protocols: Transparent, Pelco D, Pelco P, 
Everfocus, or Samsung. (NOTE: all cameras on the bus must use the same protocol
485 ID: This is the ID used by the EKB500 to send commands to the DVR. On an RS485 connection, every 