Security 
Page 4-7
Facility Restriction Levels and Remote Access 
4
The system manager sets the options listed below for the remote access default 
COR on his or her own system. If the system is linked to the network by tandem 
tie facilities (analog, T1-emulated voice, or data), the settings are assigned to all 
tie trunks. If only tandem PRI trunks link the system to the network, the settings 
are assigned to all non-tie trunks. If both tandem tie and tandem PRI trunks are 
connected to a system, the default COR FRLs and other restrictions are assigned 
to their restrictive types of trunks. 
Barrier Code Requirement. In a network, this setting should be turned on 
in order to require barrier code entry on calls that arrive from the PSTN 
over DID or PRI dial-plan routed facilities or that are made by dialing a 
Remote Access code included in the non-local dial plan. When barrier 
codes are not required, the remaining default COR settings apply to PSTN 
calls as well as network calls. This poses a security risk and does not allow 
adequate protection against toll fraud. The barrier code requirement is 
ignored for calls on tandem trunks, but the remaining default COR setting 
does apply to such calls.
When barrier codes are required, the following restrictions can be assigned 
to individual barrier codes used on remote access calls that arrive on PSTN 
lines/trunks or that are made by dialing a Remote Access code included in 
the non-local dial plan:
— Restriction. Determines whether remote access users can make local 
and/or toll calls, and includes the following settings: Unrestricted, Toll-
restricted, and Outward-restricted.
— ARS FRL. Allows or restricts use of outgoing trunks by assigning an 
FRL. The FRL ranges from 0 (most restrictive) to 6 (least restrictive). 
— Allowed/Disallowed Lists Assignment. Disallowed Lists can be 
assigned. The factory setting is 3. Do not assign any Allowed Lists. 
Calling Restrictions. This setting determines whether local and/or toll 
calls are allowed. The factory setting is outward- and toll-restricted. To 
allow call routing to the PSTN or to another system in the network, this 
setting should be changed to unrestricted, allowing the routing of all such 
calls. 
Facility Restriction Level. Use this FRL setting by assigning a restriction 
level from 0 to 6, 0 is the most restrictive, and 6 is the least restrictive. The 
FRL value assigned here is the opposite of the FRL value assigned to an 
ARS route, where a value of 0 is the least restrictive, and a value of 6 is the 
most restrictive. The factory setting is 3. To restrict calls from using 
selected UDP or ARS routes, assign a value that is lower than the FRL 
assigned to the route. Network call routes (UDP or ARS) use this default 
COR FRL and do not use barrier codes. As long as you require barrier 
codes for the default COR setting, the barrier code FRL and not the default 
COR FRL, is applied to remote access calls that arrive on PSTN dial-plan 
routed PRI facilities or on DID trunks or that are made by dialing a Remote 
Access code included in the non-local dial plan.
Allowed List Assignment. Do not assign any Allowed Lists.