Lucent Technologies 555-230-024 Manuale Utente

Pagina di 362
Connections to ECS
Issue 5    January 1998
1-25
555-230-024
Network Connections
Lucent Technologies has been a leader in providing compatibility with the Q-SIG 
global networking protocol. This means you can connect the DEFINITY ECS with 
other switches throughout the world. Q-SIG Global Networking was developed to 
comply with the Q-SIG standards developed by the European Computer 
Manufacturer’s Association and the International Standardization Organization. It 
supports the ISDN-PRI connection from switch to switch as long as both systems 
support the same protocol options.
Lucent Technologies supports both T1 and E1 lines. As industry standards 
around the world, T1 and E1 provide the latest alternative to analog trunking. 
T1/E1 access and conversion allows simultaneous connection to both T1 (1.544 
Mbps) and E1 (2.048 Mbps). 
DEFINITY ECS’s support of ISDN-PRI, ISDN-BRI, and available public network 
services means that you can achieve full end-to-end ISDN connectivity and take 
advantage of ISDN services and features. The system provides complete ISDN 
support in one system for small systems with 20 telephones up to large systems 
with over 25,000 telephones.
DEFINITY ECS also supports connection to an Electronic Tandem Network. Dif-
ferent Electronic Tandem Network locations are connected via analog or digital 
tie trunks. For example, a T1 or E1 interface can act as a high-speed digital 
backbone for voice and data communications between Electronic Tandem Net-
work locations.
For Distributed Communications System (DCS) network connections, tie trunks 
interconnect the switches that serve the DCS complex. The tie-trunk network may 
be configured as a tandem tie-trunk network, a main/satellite/tributary network, or 
an Electronic Tandem Network. The links connecting a Distributed Communica-
tion System may also be provided across a Software Defined Network. To sup-
port DCS customers who also have ISDN-Primary Rate Interface, DEFINITY ECS 
can transport DCS messages over ISDN-Primary Rate Interface D channels. As a 
result, you are no longer limited to private-line connections between your various 
locations. You can also use public network services.
DEFINITY ECS’s support of wideband signaling allows the system to handle 
applications with transmission rates greater than 64 Kbps in a single call. This 
includes videoconferencing, Local Area Network bridging, and other wideband 
applications. The system switches wideband data at N x DS0 data rates 
— 
standard for international networking.