5. SYSTEM CONNECTOR INTERFACE
25
LZT 123 7589 R1A
Safety considerations should be taken into account. For example, 
monitoring the temperature of the battery. If the temperature of the 
battery exceeds its specification limits, battery charging must be stopped 
immediately. If the battery temperature continues to rise the application 
should be suspended or the battery disconnected.
1RWH
When charging Lithium batteries, the battery pack must have an internal 
protection circuit in accordance with the manufacturer’s instructions.
5.6 Turning the Radio Device ON/OFF and the External Power Signal
Turning the Radio Device On
Figure 5.2  On timings and VIO performance
ON/OFF pulled
up internally
through 39k
Ω
t
ON
t
VIO
t
CTS
t
PULSE
Software running…
t
PRST
VCC
ON/OFF
VIO
CTS
t
O
Symbol
Parameters
Conditions
Min.
Typ
Max
Unit
t
Reference time 
when VCC is 
within working 
limits 
(1)
VCC > 3.2V
ON/OFF = VCC
-
-
-
-
t
21
Time after t0 
when the ON/
OFF pulse can 
begin
VCC > 3.2V
0
-
-
ms