SAVE THESE INSTRUCTIONS
Remove the clear, plastic protector from the 
connector on the right side of the new 362EC 
module by grasping the tabs on the ends of 
the protector and lifting. If you are upgrading 
from a stand-alone system, also remove the 
protector from the wall-mounted PARTNER 
Endeavor processor module.
A) Slide the second module off the 
PARTNER Endeavor processor module and 
put it aside. B) Slide the 362EC module onto 
the PARTNER Endeavor processor module, 
making sure the mounting tracks interlock, as 
shown in the side view.
!
CAUTION:
Caution: Do not force the module. If the 
module does not insert easily, remove it, 
clear any obstruction, and reinsert it.
A) Label the lines and extension jacks. 
B) Connect the line and telephone cords to 
the appropriate jacks on the new module.
C) Route each cord through the hook on the 
front of its module. D) Connect the free end 
of each phone cord to the modular wall jacks 
for system extensions.
NOTE:
Connect ETR and T/R combination 
devices to the last two ports on the 
PARTNER Endeavor processor or 
362EC module.
362EC
Module
MUSIC
ON
HOLD
Combo
Combo
A) Remove the #8 sheet metal screw from 
the bottom of the wall-mounted module or 
modules. 
B) If you are upgrading an existing 
stand-alone system, skip to Step 4B.
Attach the 2-Slot carrier to the top right side 
of the two modules:
A) Align the carrier carefully and then push 
firmly until the connectors on the modules 
snap into the carrier.
B) Fasten the carrier to the modules using 
the two #4 screws included with the carrier.
Press the power cord firmly into the power 
jack on the carrier. Plug the other end of the 
power cord into a properly grounded 
three-prong wall outlet not controlled by a 
switch.
If you are replacing the second module in a 
two-slot carrier, remove the two #4 screws 
holding the carrier in place and gently pull 
the carrier off the modules.
Insert the 3 1/2" #8 screw into the bottom of 
the modules. Tighten it until the mounting 
tracks of the PARTNER Endeavor processor 
module are flush against the wall with a 3/8" 
(1 cm.) gap between the wall and the rest of 
the PARTNER Endeavor processor module. 
Do not overtighten, the modules will warp.
Check the green lights on the fronts of the 
modules. If a single light is out, power down 
the carrier, then power up the carrier. If both 
lights are out, power down the carrier, reseat 
both modules, then power up the carrier. If 
the lights are still out, in the Continental U.S., 
call the hotline at 1-800-721-7071. Outside 
the Continental U.S., contact your Lucent 
Technologies Representative or local 