DKS Enterprises 1815 Manuale Utente

Pagina di 67
SYMPTON POSSIBLE 
SOLUTION(S) 
Cannot get into 
programming mode. 
• 
Wrong master code entered.  Start over. 
• 
Waiting too long between pushing buttons.  Enter information quicker. 
• 
Keypad is not plugged into board correctly.  Cable points down. 
• 
Memory chips are installed upside down. 
System emits a long 
tone and cancels 
programming. 
• 
Waiting too long between pushing buttons. 
• 
Forgetting to press # first when programming. 
Keypad is dead. 
• 
No power.  Check for 16 VAC input power. 
• 
Check that the keypad is properly connected to the circuit board.  The cable on 
the plug points down when connected to the circuit board. 
Buzz or noise on the 
phone line. 
• 
Disconnect the phone line from the system and check it with a handset.  If line 
is noisy, problem is with the phone line and not the entry system. 
• 
Check for any shorts to ground behind the circuit board. 
• 
Check for pinched wires near the door hinge. 
• 
Check for 16-volt power shorted to ground. 
• 
Check for phone line shorted to ground. 
• 
Check that phone wires are twisted. 
• 
Check that the proper type of phone wire was used for an outdoor and / or 
underground application. 
• 
Check that all wires, speaker, keypad, etc. are isolated from ground. 
• 
Check that the cabinet is properly grounded.  Be sure that case ground 
(terminal 3) is not used as a low voltage common. 
• 
Check for excessive voltage drop on 16 VAC power. 
Ringing or howling 
from the speaker. 
• 
Feedback improperly adjusted (4.2). 
• 
Volume is set too high (4.1). 
After dial out, dial tone 
is heard on the 
speaker. 
• 
Phone line is a rotary-dial line.  Have the phone company change it to a touch-
tone line. 
Door strike locks on. 
• 
Excessive voltage-drop on 16 VAC line. 
• 
Using a transformer with too low VA rating. 
• 
Relay strike time programmed too long (3.3.1). 
Door strike or gate 
operator holds open. 
• 
System was given a hold open command.  Call the system and press the tone 
deactivate number (5.3.1). 
Entry system will not 
answer when called. 
• 
Ring pin is not installed (4.8). 
• 
Bad phone line or insufficient ring voltage. 
Rotary dial 9 will not 
activate relay. 
• 
Adjust click sensitivity (4.3). 
Touch-tone 9 will not 
activate relay. 
• 
Re-program tone-open number to 9 (3.3.3). 
• 
If resident phone emits a short pulse rather than a long tone, press 9 twice in 
rapid succession 99. 
• 
Try another phone that is known to work. 
• 
Lower speaker volume (4.1) and re-adjust feedback (4.2). 
Relay activates but 
gate operator will not 
open. 
• 
Re-program relay strike time for a longer period (3.3.1). 
• 
Check wiring to gate operator. 
• 
Check gate operator. 
Postal switch will not 
activate relay. 
• 
Be sure that the wire-tie has been clipped off the postal switch. 
• 
Be sure that the relay has been programmed for postal switch input (3.3.4). 
 
 
 
60