Hanging Screen 
When locating viewing surface and checking clear ance for screen operation, 
remember surface is centered in the length of the case. Regardless of 
mounting method used, the following points apply:
➀ Mounting brackets are packed separately in carton. Engage each bracket 
  with top of housing as shown below and tighten set screws. A bracket 
  should be within 46 cm of each end of screen case. Brack ets can be 
  removed and case mounted with lag screws through top of case (holes 
  drilled on site).
➁ Screen should be positively and securely supported so that vibration or 
  even abusive pulling on viewing surface will not weaken in stal la tion.
➂ Installer must insure that fasteners used are of adequate strength and 
  suitable for the mounting surface chosen. Supporting hardware (chains, 
  cables, rods, etc.) must be essentially vertical.
➃ Entire bottom of case must be readily accessible after in stal la tion is 
 complete.
Electrical Con nec tions
Screen operates on 220V AC, 50 Hz., 1 ph cur rent.
Junction box is lo cat ed just above the bottom access panel at left end of 
screen (stan dard, right end may be specifi ed). 
Remove the bottom access panel for access to the junction box cover. (See 
Bottom Access Panel Removal instructions below). Remove four (4) hex head 
screws that secure the cover to the junction box to expose the ter mi nal strip 
per wiring diagram on page 4.
If optional low voltage control or video interface control is specifi ed and factory 
installed, please refer to wiring diagram on page 3.
Screen is shipped with internal wiring complete and control switch(es) fully 
boxed. Wire to connect screen to switch(es) and switch(es) to power supply 
should be furnished by installer. Con nec tions should be made in ac cor dance 
with attached wiring diagram, and wiring should comply with national and 
local electrical codes.
All operating switches should be “off” before power is connected.
Caution
➀ Read instructions through completely before proceeding; keep them 
  for future reference. Follow instructions carefully. Installation con trary to 
 instructions 
in 
val i dates warranty. Care in mounting and correct operation 
  will mean long and satisfactory service from your Draper screen.
➁ Allow enough access to remove front cover should fabric be come 
  damaged or should other service be required.
➂ Screen should be installed level (using a carpenter’s level).
➃ Nothing should be fastened to screen dowel or viewing surface
➄ Operating switch(es) is packed separately in screen carton. Do not 
  discard with packing material.
➅ Screen operates on 220V AC, 50 Hz., 1ph. current.
NOTE: Screen has been thoroughly inspected and tested at factory and 
found to be operating properly prior to shipment.
Bottom Access Panel Installation/Removal
Bottom access panel hooks over the lower in side edge of the screen hous ing 
and then is pivoted downward until the engagement brackets on each end of 
the bottom panel click into place with the ball detents on each endcap. Make 
sure bottom access panel clicks in place at each end of its length.
Remove bottom access panel by pushing up at each corner of panel ad ja cent 
to slot in bot tom of the hous ing.
With bot tom ac cess panel an gled up ap prox i mate ly at 20° it can be lift ed off of 
the lip of the housing and then lowered out of the housing completely.
With bottom access panel 
angled up approx. 20 degrees, 
engage hook on the panel 
with lip of the housing
Using the hook and lip as a pivot, 
pull the panel downward until the 
engagement brackets click into 
place with the ball detent 
on each endcap
Engagement bracket 
(one on each end of the 
bottom access panel)
Access case as seen from below
Bottom flange of Access housing
Bottom access panel pushup 
points for panel removal
➄ Front, back and top of case must be straight—not forced to warp or bow. 
➅ If case is painted on location, removal of roller/fabric assembly is 
  recommended prior to painting. If not removed, slot on bottom of case 
  should be shield ed to protect view ing surface from paint splatters or 
 overspray.
➆ Do not seal unit in ceiling until elec tri cal con nec tions have been made and 
  screen has been op er at ed successfully.
 
 
 
 
If you encounter any diffi culties installing or ser vic ing your Access screen, call your 
dealer or Draper, Inc., in Spiceland, Indiana, 765/987-7999 or fax 765/987-1689.
Typical 
Installation
Alternate 
Installation
(additional 
set of 
brackets 
required)
Slots along 
top of case 
permit 
brackets to 
be set at an 
angle
Case dimensions 