Moxa Technologies TCF-142-S(-T) Dépliant

Pagina di 2
 
— 4 — 
— 5 — 
— 6 — 
Connecting 2-wire RS-485 Serial Devices 
RS-485
Rx
Tx
Rx
Tx
RS-485
GND
Data-
Data+
GND
D-
D+
TCF-142
TCF-142
Serial
Device
Serial
Device
D-
GND
D+
Data-
GND
Data+
Copper
Copper
Fiber
 
Connecting RS-232 Serial Devices 
PC
Tx
Rx
GND
Copper
Copper
Fiber
RS-232
Rx
Tx
Rx
Tx
GND
Rx
Tx
RS-232
Tx
GND
CTS
RTS
DSR
DTR
Rx
Tx
Rx
CTS
RTS
DSR
DTR
GND
TCF-142
TCF-142
Serial
Device
 
6. Switch Settings 
There are 4 DIP switches on the top end of the TCF-142. SW1 and SW2 
are used to set the serial interface. SW3 is used to enable or disable the 
120 Ω termination resistor. SW4 is used to enable “Ring” mode or enable 
“Point to Point” mode. 
ON
1 2 3 4
Serial Connection 
SW1 
SW2
 
RS-232 ON 
OFF
RS-422 OFF 
OFF
RS-485 4-wire 
OFF 
OFF
RS-485 2-wire 
OFF 
ON
 
Built-in 120 Ω 
Terminator 
SW3
 
Enable ON 
Disable OFF
 
 
SW4
 
Ring mode 
ON 
Point to Point 
mode 
OFF
 
 
ATTENTION 
For Fiber Ring Users: 
To avoid problems when setting up a fiber ring, each TCF-142 unit 
making up the ring must be powered down and set to “Ring mode.” Next, 
make sure all cables are connected properly, and then power up all 
devices connected to the ring. After
 
powering up the TCF-142 units, if 
the Rx LEDs of the converters glow continuously, power down and then 
power up ONE of the TCF-142 units in the ring to return the network to 
normal operation. 
 
NOTE  “Ring Mode” can only be sued for half-duplex applications 
(e.g., RS-485 multi-drop communication). 
The DIP switch array called DIP-2 is located inside the TCF-142. DIP-2 
has two DIP switches used to adjust the pull high/low resisters.   
NOTE: SW1 and SW2 should be set both to ON, or both to OFF. 
 
Pull High/Low Resister
DIP-2 SW1 
DIP-2 SW2 
 
150K (default) 
OFF 
OFF 
1K ON 
ON 
 
NOTE  When termination is enabled, we recommend using the 1K 
(ON/ON) setting. 
 
7. LED Description   
There are 3 LEDs on the front panel of the TCF-142. 
LED 
Color 
Function 
 
PWR 
Red 
Steady ON: Power is ON 
Fiber Tx Green 
Blinking when fiber is transmitting data 
Fiber Rx Orange 
Blinking when fiber is receiving data 
8. Specifications 
Model Name 
TCF-142-S, TCF-142-S-T,   
TCF-142-M, TCF-142-M-T 
Serial Communication 
Signals for RS-232 
TxD, RxD, SGND 
Signals for RS-422 
TxD+, TxD-, RxD+, RxD-, SGND 
Signals for 4-wire RS-485 
TxD+, TxD-, RxD+, RxD-, SGND 
Signals for 2-wire RS-485 
Data+, Data-, SGND 
Baudrate 
300 bps to 921.6 Kbps 
Surge protection 
15 KV ESD 
Fiber Communication 
Connector type 
ST 
Distance 
TCF-142-S: Single mode fiber for 40 km 
TCF-142-M: Multi mode fiber for 5 km 
Support Cable 
TCF-142-S: 
8.3/125, 8.7/125, 9/125 or 10/125 μm 
TCF-142-M: 
50/125, 62.5/125, or 100/140 μm 
Wavelength TCF-142-S: 
 
1310 
nm 
TCF-142-M:   850 nm 
TX Output 
TCF-142-S:   
> -5 dBm 
TCF-142-M:    > -5 dBm 
RX Sensitivity 
TCF-142-S:   
-25 dBm 
TCF-142-M:   -20 dBm 
Point-to-Point Transmission
Half or Full duplex 
Multi-drop Transmission 
Half duplex, fiber ring 
Environmental 
Operating Temperature 
0 to 60
°C (32 to 142°F), 5 to 95 % RH 
Extended Operating 
Temperature (for -T models)
-40 to 75
°C (-40 to 167°F) 
Storage Temperature 
-20 to 85
°C (-4 to 185°F), 5 to 95 % RH 
Power 
Input Power Voltage 
12 to 48 VDC * 
Power Line Protection 
1 KV Burst (EFT), EN61000-4-4 
1 KV Surge, EN61000-4-5 
Reverse Power Protection 
Protects against V+/V- reversal 
Over Current Protection 
Protects against 2 signals shorted together: 1.1A 
Power Consumption 
100 mA at 12 VDC 
Mechanical 
Dimensions (W 
× D × H) 
67 
× 100 × 22 mm 
90 
× 100 × 22 mm (including ears) 
Material Aluminum 
(1 
mm) 
Gross Weight 
140g 
Regulatory Approvals 
CE Class 
FCC 
Part 15 sub Class B 
TÜV EN 
60950 
UL UL 
60950 
EMI 
EN55022 1998, Class B 
EMS EN61000-4-2 
(ESD), 
Criteria A, Level 2 
EN61000-4-3 (RS), Criteria A, Level 2 
EN61000-4-4 (EFT), Criteria A, Level 2 
EN61000-4-5 (Surge), Criteria A, Level 3 
EN61000-4-6 (CS), Criteria A, Level 2 
Free fall 
IEC 60068-2-32 
 
WARNING 
1. This unit is not meant to be sold to consumers. It will only be shipped 
to manufacturers or factories. 
2. The DC source should come from an external adapter or 12 to 48 VDC 
source (not from DC mains) by using a transfer device. 
3. This unit should be installed or set up by a qualified service person. 
 