Transition Networks AR-CF-02 Dépliant
Installation NOTES
Install Coax Copper
STAR TOPOLOGY
•
MAXIMUM coax segment to active hub is 600 meters (2000
feet) on RG-62 cable; minimum does not apply.
BUS TOPOLOGY
•
Devices attached to coax bus must be located AT LEAST six
(6) feet apart.
•
MAXIMUM coax bus length is 300 meters (1000 feet);
minimum is 1.8 meters (6 feet).
•
Device(s) attached to EACH END of bus must be terminated.
NOTE: If the media converter is installed at one end of the
bus, use the configuration switch to terminate the media
converter.
CONFIGURATION SWITCH
NOTE: Set configuration switch (located on the side of media converter)
according to site installation requirements:
according to site installation requirements:
Switch 1
NOT USED
Switch 2
UP = OFF
Media converter TRANSFERS signal
DOWN = ON
Media converter TERMINATES signal.
Install Fiber
•
Connect one end of first fiber cable to AR-CF-02 media
converter TX connector.
•
Connect other end of that fiber cable to second AR-CF-02
media converter RX connector.
•
Connect one end of second fiber cable to AR-CF-02 media
converter RX connector.
•
Connect other end of that fiber cable to AR-CF-02 media
converter TX connector.
Power
•
Locate correct power supply adapter for site installation.
•
Connect media converter power connector at end of power
supply adapter cord to AR-CF-02 media converter power
receptacle.
supply adapter cord to AR-CF-02 media converter power
receptacle.
•
Connect 2-prong or 3-prong external power connector on
other end of power supply adapter cord to external AC power.
other end of power supply adapter cord to external AC power.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE
MULTIMODE
Fiber Optic Cable Recommended:
Fiber Optic Cable Recommended:
62.5 / 125 µm multimode fiber
Fiber Optic Transmitter Power:
min: -19.0
dBm
max: -14.0
dBm
Fiber Optic Receiver Sensitivity:
min: -32.5
dBm
max: -14.0
dBm
Wavelength:
850nM
Bit error rate:
≤
10
-9
Maximum Cable Distance:
2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended:
Fiber Optic Cable Recommended:
9 µm singlemode fiber
Fiber Optic Transmitter Power:
min: -27.0
dBm
max: -17.0
dBm
Fiber Optic Receiver Sensitivity:
min: -32.5
dBm
max: -13.0
dBm
Wavelength:
1300nM
Bit error rate:
≤
10
-9
Maximum Cable Distance:
8 kilometers
COAX CABLE/STAR TOPOLOGY
RG-62 Cable
Cable Characteristics:
Cable type:
Coaxial RG-62/u
Impedance: 75
Ω
@ 10 MHz
Mutual Capacitance:
13 pF/ft ±20% @ 10 MHz
Maximum Attenuation:
5.5 dB/1000 feet
Maximum Cable Distance:
600 meters (2000 feet)
Minimum Distance/Connection:
0 meters (0 feet)
RG-59 Cable
Cable Characteristics:
Cable type:
Coaxial RG-59/u
Impedance: 93
Ω
@ 10 MHz
Mutual Capacitance:
13 pF/ft ±20% @ 10 MHz
Maximum Attenuation:
7.0 dB/1000 feet
Maximum Cable Distance:
450 meters (1500 feet)
Minimum Distance/Connection:
0 meters (0 feet)
COAX CABLE/BUS TOPOLOGY
RG-62 Cable
Cable Characteristics:
Cable type:
Coaxial RG-62/u
Impedance: 93
Ω
@ 10 MHz
Mutual Capacitance:
13 pF/ft ±20% @ 10 MHz
Maximum Attenuation:
5.5 dB/1000 feet
Maximum Cable Distance:
300 meters (1000 feet)
Minimum Distance/Connection:
1.8 meters (6 feet)