Transition Networks AR-CF-02(SC) Dépliant

Pagina di 2
Installation NOTES
Install Coax Copper
STAR TOPOLOGY
MAXIMUM coax segment to active hub is 600 meters (2000
feet) on RG-62 cable; minimum does not apply.
BUS TOPOLOGY
Devices attached to coax bus must be located AT LEAST six
(6) feet apart.
MAXIMUM coax bus length is 300 meters (1000 feet);
minimum is 1.8 meters (6 feet).
Device(s) attached to EACH END of bus must be terminated.
NOTE: If the media converter is installed at one end of the
bus, use the configuration switch to terminate the media
converter.
CONFIGURATION SWITCH
NOTE: Set configuration switch (located on the side of media converter)
according to site installation requirements:
Switch 1
NOT USED
Switch 2
UP = OFF
Media converter TRANSFERS signal
DOWN = ON
Media converter TERMINATES signal.
Install Fiber
Connect one end of first fiber cable to AR-CF-02 media
converter TX connector.
Connect other end of that fiber cable to second AR-CF-02
media converter RX connector.
Connect one end of second fiber cable to AR-CF-02 media
converter RX connector.
Connect other end of that fiber cable to AR-CF-02 media
converter TX connector.
Power
Locate correct power supply adapter for site installation. 
Connect media converter power connector at end of power
supply adapter cord to AR-CF-02 media converter power
receptacle.
Connect 2-prong or 3-prong external power connector on
other end of power supply adapter cord to external AC power.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following: 
FIBER CABLE 
MULTIMODE
Fiber Optic Cable Recommended:
62.5 / 125 µm multimode fiber
Fiber Optic Transmitter Power:
min: -19.0 
dBm
max: -14.0 
dBm
Fiber Optic Receiver Sensitivity:
min: -32.5 
dBm
max: -14.0 
dBm
Wavelength:
850nM
Bit error rate:
10
-9
Maximum Cable Distance:
2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended:
9 µm singlemode fiber
Fiber Optic Transmitter Power:
min: -27.0 
dBm
max: -17.0 
dBm
Fiber Optic Receiver Sensitivity:
min: -32.5
dBm
max: -13.0 
dBm
Wavelength:
1300nM
Bit error rate:
10
-9
Maximum Cable Distance:
8 kilometers
COAX CABLE/STAR TOPOLOGY
RG-62 Cable 
Cable Characteristics: 
Cable type:
Coaxial RG-62/u
Impedance: 75 
Ω
@ 10 MHz 
Mutual Capacitance:
13 pF/ft ±20% @ 10 MHz
Maximum Attenuation:
5.5 dB/1000 feet
Maximum Cable Distance:
600 meters (2000 feet)
Minimum Distance/Connection:
0 meters (0 feet)
RG-59 Cable 
Cable Characteristics: 
Cable type:
Coaxial RG-59/u 
Impedance: 93 
Ω
@ 10 MHz 
Mutual Capacitance:
13 pF/ft ±20% @ 10 MHz
Maximum Attenuation:
7.0 dB/1000 feet
Maximum Cable Distance:
450 meters (1500 feet)
Minimum Distance/Connection:
0 meters (0 feet)
COAX CABLE/BUS TOPOLOGY
RG-62 Cable 
Cable Characteristics: 
Cable type:
Coaxial RG-62/u
Impedance: 93 
Ω
@ 10 MHz 
Mutual Capacitance:
13 pF/ft ±20% @ 10 MHz
Maximum Attenuation:
5.5 dB/1000 feet
Maximum Cable Distance:
300 meters (1000 feet)
Minimum Distance/Connection:
1.8 meters (6 feet)
AR-CF-02