Manuale UtenteSommarioTable of Contents7Introduction191.1 Description of Manual19Section 1 - Introduction19Section 2 - Installation and Startup20Section 3 - Getting Started20Section 4 - Control Functions20Section 5 - Application Functions21Section 6 - Chromatogram Viewer21Section 7 - Reports21Section 8 - Logs21Section 9 - Data Collection22Section 10 - Modbus Test22Appendix A, PC Config Report23Appendix B, Component Data Table23Appendix C, Data Computations23Appendix D, Analog Output Cal. 2350A GC23Appendix E, Upgrade 2350A GC S/W and 2350 EPROMS23Appendix F, Modbus Reg. List for 2350A GC231.2 Description of Online Help241.3 Description of MON200024Installation and Setup272.1 System Requirements272.2 Installing MON2000292.3 Installing the CrypKey License Service for MON2000 PLUS302.4 Copying MON2000 to Disks302.5 Transferring a MON2000 PLUS License322.6 Uninstalling MON2000412.7 Starting MON2000432.8 Performing Your First Logon442.8.1 The Initial Logon442.8.2 Registering MON2000452.8.3 Update MON2000472.9 Checklist for Setting Up MON2000482.10 Communications482.10.1 Connect to the GC Unit482.10.2 Disconnect from GC Unit492.11 Customizing MON2000502.11.1 Configure Users502.11.2 Set Up GC Directory532.11.3 Dial-up Connection562.11.4 Modem Initialization Strings/Setup62Black Box - Modem 32563U.S. Robotics Sportster64GVC/MaxTech 28.8 Kbps Modem662.12 2350 to 2350A Retrofit Instructions672.13 Conversion Process692.14 BASIC 2350A CONFIGURATION752.15 2350A Options782.15.1 The COM4A Board782.15.2 2350A Modem Installation812.15.3 2350A Ethernet Installation842.15.4 Ethernet TCP/IP Settings882.15.5 MON2000 TCP/IP Settings902.16 CONNECT VIA GC EXTERNAL MODEM922.16.1 Hardware Setup922.16.2 Select Program Settings942.16.3 Generate PC Config Report962.17 Downloading an Application982.18 Upgrading Flash1012.19 Offline Edit of GC Application1022.19.1 File Selection1032.19.2 Upload Application1042.19.3 Upload BOS107Getting Started1093.1 Logging On1093.2 Logging Off1113.3 MON2000 User Interface1113.3.1 Main Window1123.3.2 GC Status Bar1133.3.3 View Menu1163.3.4 ToolTips1163.3.5 Data Entry and Function Features1163.3.6 Shortcut to Save or Print Data1173.4 Keyboard Shortcuts1173.5 Procedures Guide1193.6 Keylock Switch Control1233.7 Configuring Your Printer1243.8 Using Online Help1263.9 Operating Modes for Model 7001273.10 About MON2000127Control Functions1294.1 Auto Sequence1294.2 Single Stream1304.3 Halt1314.4 Calibration1324.5 Baseline Run1334.6 Auto BTU Start Up and Valve Timing1354.6.1 Initiating an Auto BTU Start Up Run1354.6.2 Starting a Valve Timing Run1404.7 GC Time1414.7.1 View GC Time1414.7.2 Set GC Time1424.8 Stop Now143Application Functions1455.1 System1455.2 Component Data1505.2.1 Select Standard Component(s)1545.2.2 Select Standard Values1555.2.3 Update Standard Component(s)1555.2.4 View Raw Data1565.2.5 Sort Retention Time1585.3 Timed Events158Timed Events Description158Valve Events159Integration Events159Spectrum Gain Events1605.4 User Defined1635.4.1 Numeric1635.4.2 Selection1645.4.3 Text Strings1645.5 Calculations1655.5.1 Control1655.5.2 Averages1675.5.3 User Defined1695.6 Limit Alarms171Limit Alarms Description1745.7 Discrete Alarms1755.7.1 Delayed Discrete Alarms1775.8 Streams1825.9 Analog Inputs1885.10 Analog Outputs1925.10.1 Analog Output Dialog Description1925.10.2 Changing a Variable1965.10.3 Changing the Bargraph1965.10.4 Performing a Manual Calibration1975.10.5 Performing an Automated Calibration1985.11 Discrete Inputs2005.12 Discrete Outputs2015.13 Valves2025.14 Temperature Control2055.15 FID Configuration2065.16 LOI Status Variables2105.17 Serial Ports2125.17.1 Serial Ports Configuration2155.18 GC Serial Port and Cable Configurations2185.18.1 GC DB-9 Serial to External Modem DB-252205.18.2 GC Phoenix Plug to External Modem DB-252215.18.3 Com ID2225.18.4 Registers2245.18.5 Setting Optional Base Pressures2305.18.6 Setting Optional Base Results2345.19 TCP/IP, Subnet, and Gateway Menu238Chromatogram Viewer2416.1 Chromatogram Viewer Function2416.2 Viewing a Live Chromatogram2426.2.1 From Online GC2426.2.2 From GC Archive2436.2.3 From File on Disk2446.3 Removing a Chromatogram from View2486.4 Saving a Chromatogram to Disk2486.5 Graph Functions2496.5.1 Editing the Chromatogram Graph2496.5.2 Changing Cursor Size2506.5.3 Printing the Chromatogram2516.6 Chromatogram Functions2516.6.1 Editing the Chromatogram2526.6.2 Editing TEVs from CGM Viewer2536.6.3 Editing Retention Times from CGM Viewer2556.6.4 Editing TEVs from Cursor2556.6.5 Viewing the Chromatogram Results2566.6.6 Entering a Description2586.6.7 Forcing a Calibration2596.6.8 Toggling TEVs and CGM Components2596.7 Viewing Baseline Data2606.8 Viewing RAW Data2616.9 Display Options261Reports2637.1 Report Display2637.1.1 View Report from Live Data2637.1.2 View Report from File2667.1.3 Print Report2687.1.4 Save Report to Disk2687.1.5 Report Contents270Analysis Report271Raw Data Report273Calibration Report274Final Calibration Report275Average Reports276Sample 24-Hour Average Report2767.2 GC Report Request2777.3 GC Printer Control2787.4 MON2000 Printer Control2807.5 Archive Data2827.5.1 View Data Model 500/Model 7002837.5.2 Archive Export Data2867.5.3 Reset2897.6 Trend Data2907.6.1 Trend Data Model 700/2350A GCs2907.6.2 View Live Trend Online Model 700/2350A2917.6.3 View Trend from File on Disk2947.6.4 Edit Graph Display2967.6.5 Changing Cursor Size2967.6.6 Describe Trend2977.6.7 Print Trend2977.6.8 Save Trend2987.6.9 Read Trend Archive2987.6.10 Display Options299Logs3018.1 Maintenance Log3018.2 Parameter List3038.3 Alarm Log3068.4 Clear or Acknowledge Active Alarms3098.5 Event Log309MON2000 Plus Data Collection/Auto-Polling3119.1 Overview3119.2 Data Collection Configuration3139.2.1 Create a New Polling Control File3169.2.2 Open an Existing Polling Control File3179.2.3 Await Command3199.2.4 Connect/Logon Command3209.2.5 Connect/No Logon Command3219.2.6 Delay (Seconds) Command3219.2.7 Delay (Hours) Command3229.2.8 Disconnect Command3239.2.9 End Command3239.2.10 Poll Command: Alarms3249.2.11 Poll Command: Averages3269.2.12 Poll Command: CGM Archive3299.2.13 Poll Command: CGM on Alarm3319.2.14 Poll Command: Condition Start3319.2.15 Poll Command: Condition End3339.2.16 Poll Command: Event Log3349.2.17 Poll Command: Maintenance Log3369.2.18 Poll Command: Registers3389.2.19 Poll Command: Reports3429.2.20 Repeat Command3449.2.21 Run Command3459.3 Data Collection3459.3.1 Start Auto-Sequencing3469.3.2 Transaction Log3489.3.3 Auto-Sequencing Status3489.3.4 Status Log349Modbus Test35110.1 Starting WinMB35110.2 Establishing Communications35210.2.1 Comparison of Modbus Protocols35310.2.2 Set GC Com Parameters via MON200035410.2.3 Set Up Port via WinMB35510.3 Getting Modbus Data35710.3.1 Use Single Data Type35910.3.2 Use Template (Mixed Data Types)36010.4 Using Modbus Data36310.4.1 Set Log Parameters36410.4.2 Save Modbus Data36610.4.3 Assign Scale Ranges for User_Modbus36710.4.4 Print Modbus Data36710.5 Troubleshooting Communication Errors36810.6 Using Modbus Test Online Help36910.6.1 How to Access36910.6.2 How to Navigate370Appendix A, PC Config Report371A.1 How to Print371A.2 Example Report372Appendix B: Component Data Table433Appendix C, Data Computations445C.1 Data Acquisition445C.2 Peak Detection446C.3 Analysis Computations449C.3.1 Conc. Analysis with Response Factor449Calibration449Calc. in Mole Percent w/o Normalization451C.4 Post Analysis Computations453C.4.1 Liquid Equivalent Computations453C.4.2 Heating Value Calculations453C.4.3 Multi-Level Calibration461C.4.4 Indirect Calibration462Appendix D, Analog Output Cal. For 2350A465D.1 Calibrating by Volts465D.2 Calibrating by Percentages469Appendix E, Upgrade 2350A GC S/W and 2350 EPROMS473E.1 Connect to GC and Halt Analysis473E.2 Offline Edit to Upload App. & Rename473E.3 Upgrade User-Defined Applications475E.4 Upgrade from Disk475E.4.1 Upgrade from GC Controller478E.4.2 Configure GC Connection481E.5 Disconnect Power and Disassemble482E.6 Replace EPROMS/Reset CPU484E.7 Reassembly Procedures485E.8 Set-Up and Programming486E.8.1 Procedure486E.8.2 Reprogramming the DiskOnChip488E.8.3 GC Reassembly489E.9 Connect to GC for Upgraded App.490E.10 Guide to Standard Application Files491E.10.1 Importance of Standard Application Files491E.10.2 Standard Applications v1.50 and Later492E.10.3 Standard Applications Prior to v1.50494Appendix F, Modbus Reg. List for 2350A GC495F.1 Introduction - SIM_2251 & User_Modbus495F.1.1 Notes on User_Modbus495F.1.2 Notes on SIM_2251 Modbus496F.2 User_Modbus Register List497F.2.1 SIM_2251 Modbus Register List500Dimensioni: 5,66 MBPagine: 516Language: EnglishApri il manuale