Manuale UtenteSommarioHP 16500C—At a Glance2In This Book5Contents7Triggering11To store and time the execution of a subroutine13To trigger on the nth iteration of a loop15To trigger on the nth recursive call of a recursive function16To trigger on entry to a function18To capture a write of known bad data to a particular variable20To trigger on a loop that occasionally runs too long21To verify that all stacks and registers are restored correctly before exiting a subroutine22To trigger after all status bus lines finish transitioning23To find the nth assertion of a chip select line24To verify that the chip select line of a memory chip is strobed after the address is stable25To trigger when expected data does not appear on the data bus from a remote device when requested26To test minimum and maximum pulse limits28To detect a handshake violation30To detect bus contention31Cross-Arming Trigger Examples32To examine software execution when a timing violation occurs33To look at control and status signals during execution of a routine34Intermodule Measurements35Intermodule Measurement Examples38To set up a group run of modules within the HP 16500C38To start a group run of modules from an external trigger source40To start an external instrument on command from a module within the HP 16500 and 16501 mainframe42To see the status of a module within an intermodule measurement44To see time correlation of each module within an intermodule measurement46To use a timing analyzer to detect a glitch48To capture the waveform of a glitch49To capture state flow showing how your target system processes an interrupt50To test a circuit using stimulus-response51To use a state analyzer to trigger timing analysis of a count-down on a set of data lines52To monitor the activity of two coprocessors in a target system53Special displays55To interleave trace lists56To view trace lists and waveforms together on the same display58Skew Adjustment60To adjust for minimum skew between two modules involved in an intermodule measurement61File Management63Transferring Files Using the Flexible Disk Drive65To save a measurement configuration66To load a measurement configuration68To save a trace list in ASCII format70To save a menu or measurement as a graphic image72To load system software74Using the LAN Interface75To set up the HP 16500C76To transfer data files from the HP 16500C system to your computer78To transfer graphics files from the HP 16500C system to your computer80Concepts81The Trigger Sequencer83The Inverse Assembler90Configuration Translation for Analyzer Modules93If You Have a Problem97Analyzer Problems99Intermittent data errors99Unwanted triggers99No Setup/Hold field on format screen100No activity on activity indicators100Capacitive loading100No trace list display101Preprocessor Problems102Target system will not boot up102Slow clock103Erratic trace measurements103Inverse Assembler Problems105No inverse assembly or incorrect inverse assembly105Inverse assembler will not load or run106Intermodule Measurement Problems107An event wasn’t captured by one of the modules107Messages108“Default Calibration Factors Loaded” (HP 16540, 16541, and 16542)108“. . . Inverse Assembler Not Found”108“Measurement Initialization Error”109“No Configuration File Loaded”110“Selected File is Incompatible”110“Slow or Missing Clock”110“State Clock Violates Overdrive Specification”111“Time from Arm Greater Than 41.93 ms”111“Waiting for Trigger”112Application Notes113Glossary117Index125Dimensioni: 711 KBPagine: 130Language: EnglishApri il manuale