Guida All'Installazione RapidaSommarioHP Performance Optimized Datacenter 20c Site Preparation and Requirements Guide—International1Abstract1Notice2Contents3Overview5About this document5Safety and IEC compliance5Site assessment6Site preparation6Site safety and security6Fire detection and suppression6HP POD 20c capacities7HP POD 20c capacity limitations7Electrical power capacities (critical IT power)7Mechanical cooling capacities7Overall system capacities7Site requirements8Site pad8HP POD 20c weight8Dimensions and clearances8Future expansions10Grounding requirements11Utilities12Humidifier water supply12Drainage13Chilled water supply13Piping materials14Power infrastructure installation14Site electrical system15Electrical power system configuration15Supported facility connections16Environmental control system16Additional POD connections16Connection portals16Humidifier17HP POD 20c access control18Fire, safety, and access notifications18Fire box18Demarcation box19Environmental considerations21Environmental risks21Cold weather21Areas prone to lightning or power surges21Seismic activity21Site plan requirements and actions22Completing a site assessment22HP Site Preparation Drawing Package22Zoning and permit requirements22Project coordination22Site planning23HP POD 20c installation23Installation equipment staging23HP POD 20c lifting layout23HP POD 20c lifting requirements24HP POD 20c storage requirements24Additional structures25Appendix A: HP site assessment26HP POD 20c site assessment checklist26Appendix B: Preparing for delivery29Pre-delivery tasks29Installation prerequisites29HP POD 20c site readiness checklist29Power infrastructure installation31Appendix C: Regulatory compliance notices32HP POD 20c regulatory compliance32Safety and IEC compliance32Safety and regulatory compliance33Turkey RoHS material content declaration33Ukraine RoHS material content declaration33Warranty information33Glossary34Documentation feedback36Index37Dimensioni: 348 KBPagine: 38Language: EnglishApri il manuale
Guida All'InstallazioneSommarioHP Performance-Optimized Datacenter, 6 m (20 ft) Site Requirements Information1Notice2Contents3Site requirements4About this document4Site preparation4Safety information4System utilities5Power5Drainage6Optional connections to central facility infrastructure7Environmental considerations7Environmental specifications7Lightning protection8HP POD specifications9Dimensions9Weight9Required clearances9Internal components12Water supply specifications14Water quality requirements15Water quality requirements and specifications15Acceptable water quality specifications15Piping materials16Water precautions16Condensation management16Power management17Connection requirements17Power requirements17Main input power17Main input power details18Supported facility connections19Humidifier specifications19Convenience outlets19Grounding requirements19IT cable portals20HP POD security20HP POD Environmental Control System20Fire, safety, and security notifications21Acronyms and abbreviations22Dimensioni: 272 KBPagine: 22Language: EnglishApri il manuale
Guida Di RiferimentoSommarioHP Performance Optimized Datacenter 20c Site Preparation and Requirements Guide-North America1Abstract1Notice2Contents3Overview5About this document5Safety and NEC compliance5Site assessment6Site preparation6Site safety and security6Fire detection and suppression6HP POD 20c capacities7HP POD 20c capacity limitations7Electrical power capacities (critical IT power)7Mechanical cooling capacities7Overall system capacities7Site requirements8Site pad8HP POD 20c weight8Dimensions and clearances8Future expansions10Grounding requirements11Utilities12Humidifier water supply12Drainage12Chilled water supply13Piping materials14Power infrastructure installation14Site electrical system14Electrical power system configuration15Supported facility connections16Environmental control system16Additional POD connections16Connection portals16Humidifier17HP POD 20c access control18Fire, safety, and access notifications18Demarcation box18Environmental considerations20Environmental risks20Cold weather20Areas prone to lightning or power surges20Seismic activity20Site plan requirements and actions21Completing a site assessment21HP Site Preparation Drawing Package21Zoning and permit requirements21Project coordination21Site planning22HP POD 20c installation22Installation equipment staging22HP POD 20c lifting layout22HP POD 20c lifting requirements23HP POD 20c storage requirements23Additional structures24Appendix A: HP site assessment25HP POD 20c site assessment checklist25Appendix B: Preparing for delivery28Pre-delivery tasks28Installation prerequisites28HP POD 20c site readiness checklist28Appendix C: Regulatory compliance notices31HP POD 20c regulatory compliance31Safety and NEC compliance31Safety and regulatory compliance32Warranty information32Glossary33Documentation feedback35Index36Dimensioni: 664 KBPagine: 37Language: EnglishApri il manuale
Manuale Di ServizioSommarioHP Performance Optimized Datacenter 20c Maintenance and Service Guide-China1Abstract1Notice2Contents3Illustrated parts catalog5Structural component identification5Life safety component identification6Electrical power component identification7Control cabinet component identification9HP POD 20c racks10Aisle clearances10Cold aisle clearance10Hot aisle clearance11Replaceable components for China models11Overview13Installation considerations13(Optional) Fire suppression system13Removal and replacement procedures14Buttons14EPO button14Removing the EPO button14Replacing the EPO button14DIN rail components15Control relay module15Removing the control relay module15Replacing the control relay module16Differential pressure sensor16Removing the differential pressure sensor17Replacing the differential pressure sensor17Door position devices18Magnetic contacts18Removing the magnetic contacts18Replacing the magnetic contacts18Electrical19Busway drop box19Removing the busway drop box19Replacing the busway drop box21Fans22IT cooling fan22Removing the IT cooling fan23Replacing the IT cooling fan24Ventilation fan24Removing the Rittal SK 3326 ventilation fan25Replacing the Rittal SK 3326 ventilation fan25Filters26Heat exchanger air filters26Removing the heat exchanger air filter26Replacing the heat exchanger air filter26VESDA filter27Removing the VESDA filter27Replacing the VESDA filter28Rittal SK 3326 ventilation fan filter28Removing the Rittal SK 3326 ventilation fan filter29Replacing the Rittal SK 3326 ventilation fan filter29Indicators30ECS touchscreen and EPO indicators30Removing the ECS EPO LED indicators31Replacing the ECS EPO LED indicators31Lights32LED light32Removing the LED light32Replacing the LED light32Sensors33Heat exchanger condensate drain pan sensors33Removing the drain pan sensor33Replacing the drain pan sensor34Chilled water supply and return header drain pan sensors34Removing the chilled water supply and return header drain pan sensor34Replacing the chilled water supply and return header drain pan sensor34Humidistat35Removing the humidistat35Replacing the humidistat36Humidity sensor37Removing the humidity sensor38Replacing the humidity sensor38Chilled water system temperature sensor39Removing temperature sensor from the chilled water system39Replacing the temperature sensor in the chilled water system40Chilled water temperature sensor internal components40Removing the chilled water temperature sensor internal components41Replacing the chilled water temperature sensor internal components41Temperature sensor (cold aisle)43Removing the cold aisle temperature sensor43Replacing the cold aisle temperature sensor43Temperature sensors (hot aisle)44Removing the hot aisle temperature sensor44Replacing the hot aisle temperature sensor45Fluid system components45Chilled water supply and return header pressure sensors45Removing the chilled water supply and return header pressure sensor46Replacing the chilled water supply and return header pressure sensor46Chilled water flow sensor47Removing the chilled water flow sensor47Replacing the chilled water flow sensor47Chilled water system temperature sensor48Removing temperature sensor from the chilled water system48Replacing the temperature sensor in the chilled water system49Chilled water temperature sensor internal components49Removing the chilled water temperature sensor internal components50Replacing the chilled water temperature sensor internal components50Heat exchanger51Humidifier52Removing the humidifier52Replacing the humidifier54Humidistat (if installed)56Removing the humidistat56Replacing the humidistat57Valves58External chilled water isolation valve58Removing the external chilled water isolation valve58Replacing the external chilled water isolation valve59External pressure gauge isolation valve59Removing the external pressure gauge isolation valve59Replacing the external pressure gauge isolation valve60Periodic maintenance61Periodic maintenance overview61Qualified personnel61Cooling system61Leak detection62Leak isolation62Humidifier (if installed)63ECS64Electrical64Fire alarm and suppression system66HP POD 20c structure66Life safety67Access control68Third-party components68Specifications69General HP POD 20c specifications69Electrical specifications69Water specifications70Rack specifications70Thermal and air flow performance70Environmental specifications70Optional features specifications71Contacting HP72Before you contact HP72HP contact information72Regulatory information73HP POD 20c regulatory compliance73Safety and NEC compliance73Regulatory requirements for EXIT signs74Safety and regulatory compliance75Warranty information75HP POD 20c regulatory compliance75Glossary76Documentation feedback78Index79Dimensioni: 2,31 MBPagine: 81Language: EnglishApri il manuale
Manuale UtenteSommarioHP Performance Optimized Datacenter 20c User Guide-International1Abstract1Notice2Contents3Overview6Before you begin6Operator safety6Component safety6Fire detection and suppression7Environmental considerations7Component identification8Structural component identification8Parts and part number identification8Life safety component identification9Electrical power component identification12Control cabinet component identification16HP POD 20c racks17Life safety systems18Life safety overview18EPO system18ECS touchscreen and EPO indicators19EPO modes20EPO accidental activation20Battery backup during an EPO event20VESDA air sampling smoke detection system21(Optional) Fire protection system21Manual fire button21Fire alarm indicators22Fire suppression system22Fire system operator panel22Fire suppression sequence of operations23Emergency egress24Power, electrical, and controls25Site electrical system25Power safety25Grounding25Lightning protection26Capacities27HP POD 20c capacity limitations27Electrical and mechanical cooling capacities27Power feeders27Electrical panels28Arc flash safety28Power distribution: electrical busway system28Panel schedules29Wire color code29Electrical busways30Drop boxes31Power configurations32Rack power32HP POD 20c lighting33Environmental control system34Environmental control system overview34Using the ECS34Sensors35Humidity sensors35Pressure sensors35Temperature sensors36Facility chilled water sensors38Facility connections to ECS38Connecting to the ECS38Managing the ECS from the HP POD 20c39Configuring the ECS39Logging in remotely to the ECS41Locating the ECS IP addresses42Password protection43Navigating the ECS interface43Logging in to the ECS touchscreen44Overview screen45Status Overview screen47Basic System Configuration screen47Configuring the chilled water supply temperature alarm parameters48Configuring the chilled water return temperature alarm parameters49Configuring the chilled water supply pressure alarm parameters49Configuring the chilled water supply pressure alarm parameters50Configuring the humidity alarm parameters50Configuring the cold aisle temperature alarm parameters50Configuring the hot aisle temperature alarm parameters51Configuring the differential pressure alarm parameters51Configuring the differential pressure alarm parameters51Setting the humidifier control52Setting the fan controls for each fan control zone52Advanced System Configuration screen52Setting the start-up alarm reset delay53Calibrating the flowmeter54Calibrating the differential pressure sensors54Setting the logging configuration54Setting the switchboard serial number55Setting the HP POD 20c serial number55Loading default settings55Controller Settings screen55I/O Overview screen57ECS alarms57Safety and access control alarms58Cooling system59HP POD 20c cooling system theory of operation59Water supply temperature59Water quality requirements and specifications60Cooling system components61Fans62Condensation management63Drains63Hot aisle drains64Cold aisle drains64Leak detection65IT networking and communications66Networking66Connection portals66Demarcation box66Fire box67Optional components68Fire protection system68Humidifier68Controlled access68Power up procedure69Standard HP POD 20c power up procedure69Power up checklist69Standard power up procedure70Site electrical70Site chilled water70ECS and EPO70POD operation70Cold weather HP POD 20c power up procedure70Cold weather power up checklist71Standard power up procedure71Site electrical71ECS and EPO71Site chilled water72POD heating procedure72POD operation72Power down procedure73Specifications74General HP POD 20c specifications74Electrical specifications74Water specifications75Rack specifications75Thermal and air flow performance75Environmental specifications75Maintenance77Periodic maintenance77Sample HP POD 20c maintenance schedule77Contacting HP78Before you contact HP78HP contact information78Regulatory information79HP POD 20c regulatory compliance79Safety and IEC compliance79Safety and regulatory compliance80Turkey RoHS material content declaration80Ukraine RoHS material content declaration80Warranty information80Glossary81Documentation feedback84Index85Dimensioni: 2,04 MBPagine: 86Language: EnglishApri il manuale