Istruzione Sull'InstallazioneSommarioCheck you have everything you need1Switch off the host system and connect up the MicroBar NX2Connect the data input devices to the MicroBar NX3Switch on the host system4Enter the interface number for your host system5Set up the output transmission parameters6Set up the data input parameters7Keyboard wedge—All except Wyse, DEC 220 / 320 / 4202Keyboard wedge—Wyse, DEC 220 / 320 / 4202RS-232 C / TTL2Dual RS-232 C2Predefined interface numbers—Keyboard wedge5Predefined interface numbers—RS-2325Dimensioni: 241 KBPagine: 78Language: EnglishApri il manuale
Guida Di RiferimentoSommarioASCII character codes1Beeps and LEDs14Power-up beeps and LEDs14Good read beeps / good read LED15Configuration beeps17Software version beeps and flashes17Code mark18Default code marks18Composing custom code marks19AIM symbology identifiers21Compose interface number23Which interface number?23Composing an interface number23Concatenating configuration bar codes25What is a configuration bar code?25Why concatenate?25Limitations25How to concatenate25Configuration modes27Cloning mode27Configuration Password mode28Temporary configuration mode29ScanPlus transparent configuration mode30Display data string mode31Data reformatting321. Activate reformatting and define the input data to be formatted322. Define the reformatting for the output data372.a. Quick-and-easy reformatting382.b. Advanced full-options reformatting40Default parameter settings45Glossary46Input devices47Input identification48Input identifier position48Port 1 (RS-232) / Port 3 (Keyboard Wedge)48Port 449Port 549Installation procedure50General installation / configuration procedure50Inter-character delay51Predefined delay values51Compose inter-character delay51Inter-message delay53Predefined delay values53Compose inter-message delay54Interfaces56Interface types56Identifying the interface56Keyboard wedge57Connection—All except Wyse, DEC 220 / 320 / 42057Connection—Wyse, DEC 220 / 320 / 42058Predefined interface numbers59Predefined data transmission settings63Preamble / postamble64Interpreting and transmitting special keyboard keys66End-of-transmission keyboard character status66Transmission delay66Keyboard wedge—Additional preamble / postamble characters67Keyboard wedge—Emulating special keyboard keys72Interpreting and transmitting special keyboard keys72Special keys interpretation codes73Special keys transmission codes75Laser scanner input devices76Laser trigger management76Consecutive same read data validation79Magstripe input devices80Track selection80Transmission sequence81Track separator character81Start/end sentinels81LRC check digit81Number codes82Parameter list / data strings83Interface numbers83Data transmission parameters85Input device parameters90Symbology parameters93MicroBar NX operating parameters99Data string values103Preamble / postamble110Product checklist111Reset all configuration parameters112Reset factory defaults112RS-232 input devices113Baud Rate113Data bits114Parity114Stop bits114ENQ / ACK / NAK software protocol115XON/XOFF software protocol117RTS/CTS hardware protocol117Transmission to the host system118Special keys interpretation—Output to keyboard wedge120RS-232—Output to host system124Connection—RS-232 C, RS-232 TTL124Connection—Dual RS-232 C125Predefined interface numbers126Predefined interface numbers—RS-232126Predefined data transmission settings127Baud Rate128Data bits129Parity129Stop bits129Hardware/software protocols timeout130ENQ / ACK / NAK software protocol131XON/XOFF software protocol135RTS/CTS hardware protocol136LRC (Longitudinal Redundancy Check)137Preamble / postamble138Transmission delay139RS-232—Slave mode140Activation140How to use slave mode140Software version identification142Version indications142Symbologies143Available symbologies143Default symbologies144Character formats and MicroBar NX transmission format144Barcode length and data security145Symbologies—Activation146Disable All Symbologies146Symbology activation codes147Symbologies—Ames Code150Activation150Symbologies—Codabar151Activation151Default values151Start/stop152CLSI library system152Check digit (AIM recommendation)153Concatenation155Symbologies—Code 11156Activation156Default values156Check digits156Symbologies—Code 39 (*)157Activation157Default values157Start/stop159Check digit160Multiread161Special wedge keys emulation161Symbologies—Code 93162Activation162Default values162Multiread163Symbologies—Code 128 / EAN 128164Activation164Default values164CIP 128 French pharmaceutical codes164EAN-128 norms (auto-discriminating)165Symbologies—EAN-8, EAN-13166Symbologies—EAN 128167Symbologies—Interleaved 2 of 5168Activation168Default values168Check digit169Barcode length170Symbologies—Matrix 2 of 5171Activation171Symbologies—MSI Code172Activation172Default values172Check digit172Symbologies—Plessey Code173Activation173Default values173Check digit173Symbologies—Standard 2 of 5174Activation174Default values174Check digit mod 10175Barcode length176Symbologies—Telepen177Activation177Format177Symbologies—UPC/EAN code families (*)178Activation178Default values179Add-on digits180Check digit181Transmission of number system182Re-encoding UPC-A, UPC-E, EAN-8183Test codes184One-dimensional symbologies184Troubleshooting186Before you contact your UBI representative . . .186If you still have a problem . . .186Power-up problems187Operating problems188Configuration problems190Dimensioni: 438 KBPagine: 202Language: EnglishApri il manuale