Scheda Tecnica (TPS53114EVM-541)SommarioTPS53114EVM-54111 Introduction21.1 Description21.2 Applications21.3 Features22 TPS53114EVM-541 Electrical Performance Specifications23 TPS53114EVM-541 Schematic34 Connector and Test Point Descriptions44.1 Enable Switch and Enable Sense – SW1 and JP244.2 Frequency Selection Switch and Frequency Sense – SW2 and JP144.3 Test Point Descriptions44.3.1 Input Voltage Monitoring –TP1 and TP244.3.2 Output Voltage Monitoring – TP3 and TP444.3.3 Switching (Phase) Voltage Monitoring – TP5 and TP444.3.4 Frequency Select Voltage Monitoring – TP6 and TP254.3.5 Output Capacitor Select Pin Voltage Monitoring -TP754.3.6 Soft-Start – TP8 and TP254.3.7 Enable– TP955 Test Setup (Optional)55.1 Equipment55.1.1 Voltage Source55.1.2 Meters55.1.3 Loads55.1.4 Oscilloscope55.1.5 Recommended Wire Gauge55.1.6 Other65.2 Equipment Setup65.2.1 Procedure65.2.2 Diagram75.3 Start-Up/Shutdown Procedure75.4 Output Ripple Voltage Measurement Procedure85.5 Equipment Shutdown86 TPS53114EVM-541 Test Data86.1 Efficiency86.2 Line and Load Regulation96.3 Output Voltage Ripple96.4 Switch Node107 TPS53114EVM-541 Assembly Drawings and Layout108 TPS53114EVM-541 Bill of Materials12Important Notices14Dimensioni: 6,29 MBPagine: 15Language: EnglishApri il manuale