Manuale UtenteSommarioContents7Chapter 1, Smoke control overview13Methods of smoke control14Compartmentation method14Dilution method14Pressurization method14Airflow method16Buoyancy method17Applications of smoke control methods17Zoned smoke control17Stairwell smoke control19Elevator shaft smoke control21Atrium smoke control22Underground building smoke control24Smoke detection and system activation24Zoned smoke control detection and activation25Stairwell smoke control detection and activation25Elevator smoke control detection and activation25Atrium smoke exhausting detection and activation25Design approaches to smoke control27No-smoke approach27Tenability approach27Dedicated system approach27Design considerations for smoke control28Plugholing28Smoke feedback29Chapter 2, Pre-installation considerations31Zone operating modes31Normal mode32Alarm mode32Adjacent mode32Unaffected mode32Associated equipment32Fire alarm system equipment32Fire alarm control panel34Smoke control system equipment35Equipment supervision38System testing39Automatic weekly self-testing39Manual periodic testing39Alarm response39Automatic smoke control matrix39Response times41Cable distance considerations41Chapter 3, Installation diagrams43Smoke control system overview43System riser diagrams44System termination diagrams45Tracer MP581 to FSCS wiring46Tracer MP581 to FACP wiring49Chapter 4, Installing the Tracer Summit BMTX BCU51Mounting the hardware51Operating environment requirements51Clearances52Mounting the back of the enclosure54Wiring high-voltage ac power55EMI/RFI considerations58Checking the earth ground58Connecting the main circuit board60Installing the door62Transtector, Ethernet (UUKL nondedicated only), and LonTalk connections on the BMTX BCU63Chapter 5, Installing the Tracer MP581 programmable controller65Installation guidelines65Specifications66Selecting a mounting location67Operating environment requirements67Clearances and dimensions68Mounting the back of the enclosure70Wiring high-voltage ac power71Circuit requirements71Wiring high-voltage power72EMI/RFI considerations74Checking the earth ground74Wiring inputs and outputs76Input/output wiring guidelines76Wire routing77Providing low-voltage power for inputs and outputs77Screw terminal locations78Wiring universal inputs79Wiring analog outputs80Wiring binary outputs81Checking binary inputs82Checking outputs83Checking binary outputs83Checking 0-10 Vdc analog outputs83Checking 0-20 mA analog outputs84Wiring LonTalk to the Tracer MP58186Installing the circuit board88Verifying operation and communication of the Tracer MP58191Service Pin button91Interpreting LEDs91Binary output LEDs92Service LED92Status LED93Comm LED93Installing the door94Removing the door94Chapter 6, Installing the EX2 expansion module97Storage environment98Mounting location98Terminal strips99Mounting the metal-enclosure module99AC-power wiring100Wiring AC-power to the metal-enclosure module101I/O bus wiring103Setting the I/O bus addresses105Input/output terminal wiring105Universal inputs106Binary outputs106Analog outputs (UUKL nondedicated only)106Analog output and universal input setup106Interpreting EX2 LEDs108Binary output LEDs108Status LED109Communications LEDs109Chapter 7, Programming111Response times111Operational priority112Subsequent alarms113Smoke alarm annunciation115Weekly self-test of dedicated systems117End process verification121Communication watchdog124Lamp test and audio alarm silence128Nondedicated smoke purge130Variable-air-volume system131Constant-volume system131UL-tested programs131Chapter 8, Network variable bindings133Overview133Binding network variables133Tracer MP580/581 bindings134Receiving data134Sending data134Heartbeated network variables134Custom bindings135UUKL binding list (watchdog communication)135UUKL binding list (smoke alarm status)138UUKL binding list (FCSP override control)139UUKL binding list (actuator Open/Close or On/Off status)140UUKL binding list (actuator failure status)141UUKL binding list (FSCP control)141UUKL binding list (automatic self-test trigger and status)142Custom binding report142Understanding bindings142Node143Binding types143Basic binding shapes and the hub/target system143Designing bindings145Appendix A, References153Dimensioni: 5,48 MBPagine: 156Language: EnglishApri il manuale