Zebra Technologies P1058563-003 ユーザーズマニュアル
81
WebLink Set/Get/Do Commands
weblink.ip.conn[1|2].test.test_on
10/31/13
P1058563-003
weblink.ip.conn[1|2].test.test_on
Description This command determines when the test connection should be attempted. This
assists in debugging the printer's connection to remote servers when there are issues with the
main weblink connection (conn1 or conn2).
assists in debugging the printer's connection to remote servers when there are issues with the
main weblink connection (conn1 or conn2).
^JUF, ^JUS, ^JUN, ^JUA
, and
device.restore_defaults
do not have any affect on this
setting.
Supported Devices
• iMZ 220™, iMZ 320™
• QLn220™, QLn320™, QLn420™
• ZT210™, ZT220™, ZT230™
Type
setvar, getvar, do
Commands
Details
setvar
This command indicate when the test connection should be attempted.
Format:
•
! U1 setvar "weblink.ip.conn1.test.test_on" "value"
•
! U1 setvar "weblink.ip.conn2.test.test_on" "value"
Values:
off,failure,interval,both
Default:
"failure"
getvar
This command retrieves the test connection setting.
Format:
•
! U1 getvar "weblink.ip.conn1.test.test_on"
•
! U1 getvar "weblink.ip.conn2.test.test_on"
do
This command sets when the test connection should be attempted.
Format:
•
! U1 do "weblink.ip.conn1.test.test_on" "value"
•
! U1 do "weblink.ip.conn2.test.test_on" "value"
Values:
off,failure,interval,both
Default:
"failure"