Emerson 2200S ユーザーズマニュアル

ページ / 158
Configuration and Use Manual
93
Operating the Transmitter
Op
eratio
n
App
e
ndi
ces
Mai
n
tenan
c
e and
 T
roub
le
sh
oo
tin
g
Com
m
is
si
on
in
g
With ProLink II
Table 8-3 shows how you can control the totalizers and inventories using ProLink II. 
To enable inventory reset using ProLink II:
1. Click 
View > Preferences
.
2. Check the 
Enable Inventory Totals Reset
 checkbox.
3. Click 
Apply
.
To get to the Totalizer Control screen:
1. Click 
ProLink
.
2. Select 
Totalizer Control
.
With the Communicator
Table 8-4 shows how you can control the totalizers and inventories with the Communicator.
Table 8-3
Totalizer and inventory control with ProLink II
To accomplish this
On the totalizer control screen...
Stop all totalizers and inventories
Click 
Stop
Start all totalizers and inventories
Click 
Start
Reset mass totalizer
Click 
Reset Mass Tota
l
Reset volume totalizer
Click 
Reset Volume Total
Simultaneously reset all totalizers
Click 
Reset
Simultaneously reset all inventories
(1)
(1) If enabled in the ProLink II Preferences window.
Click 
Reset Inventories
Reset mass inventory only
Click 
Reset Mass Inventory
Reset volume (liquid or gas) inventory only
Click 
Reset Volume Inventory 
or 
Reset Gas Volume Inventory
Table 8-4
Totalizer and inventory control with a Communicator
To accomplish this
Press this sequence of buttons
Stop all totalizers and inventories
Process Variables > Totalizer cntrl > Stop totalizer
Start all totalizers and inventories
Process Variables > Totalizer cntrl > Start totalizer
Reset mass totalizer
Process Variables > Totalizer cntrl > Reset mass total
Reset volume totalizer
Process Variables > Totalizer cntrl > Reset volume total
Reset all totalizers
Process Variables > Totalizer cntrl > Reset all totals