Omega Engineering FMG90 ユーザーズマニュアル

ページ / 18
 
 
 
10 Technical data 
The technical data of customised versions may differ from the data in these instructions. 
Please observe the information specified on the type plate. 
Type 
FMG 91 
FMG 92 
FMG 93 
FMG 94 
FMG 95 
FMG 96 
Measurement device characteristics 
Flow range [GPM] 
0.066…1.3 0.26…5.3 0.66…13.2 1.3…26.4  2.6…53  3.3…66 
Accuracy 
1% of reading 
Repeatability 1% 
Output signal 
starting from [GPM] 
0.02 0.07 0.27 0.52 1.05 1.3 
Max. flow rate [GPM] 
1.6  6.6  15.8  31.7 63.4 79.3 
Response time 
< 100 ms 
Indications 
red LED = Supply voltage  •  green LED = Flow 
Output signal characteristics 
Frequency output: 
- Pulse rate / K-
Factor * 
[pulses/gal] 
15000 3000 1500 750 380 300 
- Resolution * 
[ml/pulse] 
0.25 1.0 2.5 5.0 10.0 
12.5 
Square wave signal • duty cycle 50:50 
- Signal shape 
can be connected as PNP or NPN open collector 
- Signal current 
≤ 25 mA 
Electrical characteristics 
Supply voltage 
24 VDC ±15% or 12 VDC ±15% 
Power consumption 
0.6 W 
Electrical protection 
measures 
short-circuit proof   •  protected against polarity reversal  
Electrical connection 
4-pin-plug M12x1 
Degree of protection 
IP 65 (only with a connected coupling) 
Process variables 
Medium to measure 
Water and other conductive liquids 
min. conductivity of 
the medium 
20 μS/cm 
Medium temp. 
14…140 °F (not freezing) 
Ambient temp. 
41…140 °F 
Nominal diameter 
DN 8 
DN 15 
DN 20 
DN 25 
Inner diameter 
0.31 inch 
0.55 inch 
0.71 inch 
0.98 inch 
145 psi (68 °F)  •  116 psi (104 °F)  •  87 psi (140 °F) 
Max. working 
pressure (at …) 
higher pressure ratings on demand 
Process connection 
½ - 14 NPT 
¾ - 14 NPT 
1 - 11.5 NPT 
1¼ - 11.5 
NPT