Patton electronic 10100 ユーザーズマニュアル

ページ / 12
8
SmartNode 10100 Series Quick Start Guide
   2.
Login to the SmartNode using the specific credentials included on the “Important Notice” sheet that 
shipped with your unit. The management port is configured with a static Class C IP address by default.
Figure 7. 
Conneting the management interface
7.0  Configuring the SmartNode
Access the SmartNode through the Console Management port, or through the Ethernet management port. Refer 
to the following sections for more information:
7.1  Accessing the SmartNode via the Console Serial port
Logging into the SmartNode Console
   1.
To physically connect the Consol Serial port, follow the instructions in section 6.1, “Connecting the Console 
Serial port” on page 7
.
   2.
To communicate with the SN10100 through the consol port, you must first configure a terminal emulator 
or console application (such as HyperTerminal or Putty) in order to configure initial settings. Configure 
the terminal emulator with the following settings:
   3.
Login to the console using the specific credentials included on the “Important Notice” sheet that shipped 
with your unit. (If you do not have the “Important Notice” sheet, contact support@patton.com.) The fac-
tory default configuration for the Ethernet Interface IP address is 192.168.200.10/24.
Baud rate
Data rate
Parity
Stop bits
Flow control
9600
8 bits
None
1
None