Mitsubishi Electronics FX5 ユーザーズマニュアル
17 RAS FUNCTIONS
17.1 Self-Diagnostics Function
111
17
CPU Module Operation Setting
Specify the operation which the CPU module should perform when an error occurs on each intelligent function module.
Navigation window [Parameter] [System Parameter] [I/O Assignment Setting]
Window
Displayed items
LED display setting
Set whether or not to display the ERROR LED and BATTERY LED.
Navigation window [Parameter] [FX5UCPU] [CPU Parameter] "RAS Setting" "LED Display Setting"
Window
Displayed items
Item
Description
Setting range
Default
CPU Module Operation
Setting at Error
Detection
Setting at Error
Detection
Sets the CPU module operation upon the detection of major or
moderate errors in the configured module.
moderate errors in the configured module.
• Critical: Stop, Moderate:
Continue
• Critical: Stop, Moderate: Stop
• Critical: Continue, Moderate:
• Critical: Continue, Moderate:
Continue
Critical: Stop,
Moderate: Continue
Moderate: Continue
Item
Description
Setting range
Default
ERROR LED
Minor Error (Continue
Error)
Error)
Sets whether or not the ERROR LED is displayed when a minor error
occurs.
occurs.
• Display
• Do Not Display
• Do Not Display
Display
BATTERY LED
Battery Error
Sets whether or not the BATTERY LED is displayed when a battery
error occurs.
error occurs.
• Display
• Do Not Display
• Do Not Display
Display