Mitsubishi Electronics 0 ユーザーズマニュアル

ページ / 136
97
CHAPTER 10 PROGRAMMING
10
10.
2 Connec
ting 
the Module t
o t
he Head Module
(4) User devices
Device
Description
W1000 and W1001
Device to which the present value is to be written at auto refresh
W1002 and W1003
Device to which the latch count value is to be written at auto refresh
W1004 to W1005
Device to which the sampling count value is to be written at auto refresh
W1006 and W1007
Device to which the periodic pulse count previous value is to be written at auto refresh
W1008 and W1009
Device to which the periodic pulse count present value is to be written at auto refresh
W1010
Device to which the overflow status storage is to be written at auto refresh
X20
Count start signal
QX10 (X20 to X2F)
X22
Coincidence output data setting signal
X23
Preset command signal
X24
Count stop signal
X25
Coincidence LED clear signal
X26
Counter function start signal
X27
Counter function stop signal
X29
Latch execution signal
X2B
Sampling count start signal
X2D
Periodic pulse count start signal
Y30
Coincidence confirmation LED signal
QY10 (Y30 to Y3F)
Y31
Overflow occurrence confirmation LED 
signal
X1000
Module READY
LD62 (X/Y1000 to X/Y100F)
X1002
CH1 Counter value coincidence (point 
No.1)
Y1000
CH1 Coincidence signal No.1 reset 
command
Y1001
CH1 Preset command
Y1002
CH1 Coincidence signal enable command
Y1004
CH1 Count enable command
Y1006
CH1 Counter function selection start 
command
SB49
Data link status of the own station
SWB0.0
Data link status of each station (station No.1)
N0
Nesting (station No.1)
M0
Communication ready flag (station No.1)
T1 to T5
Interlock between the own and other stations