3 FUNCTION LIST
3
FUNCTION LIST
Cyclic transmission
This section describes the functions of the CC-Link system. For details on the functions, refer to the following.
MELSEC iQ-R CC-Link System Master/Local Module User's Manual (Application)
: Available,
MELSEC iQ-R CC-Link System Master/Local Module User's Manual (Application)
: Available,
: Not available
Function
Description
Availability
Master
station
station
Local
station
station
Standby
master
station
master
station
Communic
ations with
other
stations
ations with
other
stations
Communications using
RX and RY
RX and RY
Communicates I/O data in units of bits between the master station and
other stations.
other stations.
Communications using
RWr and RWw
RWr and RWw
Communicates I/O data in units of words between the master station and
other stations.
other stations.
Mode
Remote net Ver.1 mode
The mode can be selected according to the CC-Link system configuration.
Remote net Ver.2 mode
Remote device net Ver.1
mode
mode
Remote device net Ver.2
mode
mode
Remote I/O net mode
Link refresh
Automatically transfers data between the link device of the master/local
module and the device of the CPU module.
module and the device of the CPU module.
Cyclic data integrity assurance
Prevents read/write data from being separated between new and old data.
Sequence scan synchronization
specification
specification
Selects whether link scan is set to asynchronous or synchronous with the
sequence scan of the CPU module.
sequence scan of the CPU module.
Setting of the input data from a data
link faulty station
link faulty station
Selects whether I/O data from a station where a data link error occurs is
cleared or held.
cleared or held.
Output data setting for CPU STOP
Selects whether remote output (RY) is refreshed (held at the value before
STOP) or cleared to zero (0) when the CPU module is set to STOP.
STOP) or cleared to zero (0) when the CPU module is set to STOP.
Data link setting when CPU is down
Selects whether data link is stopped or continued when a stop error occurs
in the CPU module which a master/local module is mounted with.
in the CPU module which a master/local module is mounted with.
Data link stop and restart
Stops data link during debugging and other operations. (Data sending from
the own station is stopped.) Also, the stopped data link is restarted.
the own station is stopped.) Also, the stopped data link is restarted.
Remote I/O station points setting
Selects the number of refresh points with a remote I/O station from 8 points,
16 points, and 32 points when the master station is in the remote net Ver.2
mode or remote device net Ver.2 mode. Changing the number of points can
save the areas of the refresh device in a CPU module. (In modes other than
the remote net Ver.2 mode and remote device net Ver.2 mode, only 32
points per station can be selected.)
16 points, and 32 points when the master station is in the remote net Ver.2
mode or remote device net Ver.2 mode. Changing the number of points can
save the areas of the refresh device in a CPU module. (In modes other than
the remote net Ver.2 mode and remote device net Ver.2 mode, only 32
points per station can be selected.)