Mitsubishi Electronics Q68RD3-G ユーザーズマニュアル

ページ / 212
4
 - 1
4.1 Handling Precautions
 
4
PROCEDURES AND SETTINGS BEFORE SYSTEM 
OPERATION
CHAPTER4 PROCEDURES AND SETTINGS BEFORE 
SYSTEM OPERATION
4.1
Handling Precautions
(1) Do not drop or give a strong impact to the case. 
(2) Do not remove the printed-circuit board of the module from the case. 
Doing so may cause a failure.
(3) Be careful to prevent foreign matters such as cutting chips or wire chips 
from entering the module. 
Such foreign matter can cause a fire, failure, or malfunction.
(4) A protective film is attached to the module top to prevent foreign matter 
such as wire chips from entering the module during wiring.
Do not remove the film during wiring. 
Be sure to remove it for heat dissipation before system operation.
(5) Tighten the screws such as module fixing screws within the following 
ranges.
Loose screws may cause short circuits, failures, or malfunctions.
(6) To mount the module, while pressing the module mounting lever located 
in the lower part of the module, fully insert the module fixing projection 
into the hole in the base unit and press the module until it snaps into 
place. 
Incorrect module mounting may cause a malfunction, failure, or drop of 
the module.
(7) Always make sure to touch the grounded metal to discharge the 
electricity charged in the body, etc., before touching the module. 
Failure to do so may cause a failure or malfunctions of the module.
Table 4.1 Tightening torque
Screw
Tightening torque range
Module fixing screw (M3 screw)
0.36 to 0.48N•m
Connector screw (M2.6 screw)
0.20 to 0.29N•m