MDS-D/DH Series Specifications Manual
3-5 Sequence functions
3-5 Sequence functions
3-5-1 Contactor control function
With this function, the contactor ON/OFF command is output from the power supply unit (or servo/spindle 
drive unit for integrated type) based on the judgement as to whether it is in emergency stop, emergency stop 
cancel, spindle deceleration and stop or vertical axis drop prevention control, etc.
3-5-2 Motor brake control function
With this function, the brake ON/OFF command is output from the servo drive unit based on the judgement 
as to whether it is in emergency stop, emergency stop cancel or vertical axis drop prevention/pull-up control, 
etc.
When a multiaxis drive unit is connected, all the axes are simultaneously controlled.
3-5-3 External emergency stop function
Besides the emergency stop input from the NC, double-protection when an emergency stop occurs can be 
provided by directly inputting an external emergency stop, which is a second emergency stop input, to the 
power supply unit (servo/spindle drive unit for integrated type).
Even if the emergency stop is not input from NC for some reason, the contactors will be activated by the 
external emergency stop input, and the power can be shut off.
3-5-4 Specified speed output
This function is to output a signal that indicates whether the machine-end speed has exceeded the speed 
specified with the parameter.
With this function, the protection door, etc. can be locked to secure the machine operator when the machine-
end speed has exceeded the specified speed. This function can also be used for judging whether the current 
machine-end speed is higher than the specified speed.
3-5-5 Quick READY ON sequence
With this function, the charging time during READY ON is shortened according to the remaining charge 
capacity of the power supply unit. When returning to READY ON status immediately after the emergency 
stop input, the charging time can be shortened according to the remaining charge capacity and the time to 
READY ON is shortened.
CN1A 
CN4 
MDS-D/DH-CV 
CN4 
3  EMG2 
(NC) 
1  EMG1 
CN23B 
CN23A 
OPT1 
MC2 
(NC) 
MC1 
EMG 
MDS-D/DH-V1/V2/SP/SP2
SH21 cable 
(24VDC) 
External emergency   
stop switch
 
External emergency stop input 
Mitsubishi NC 
G391 cable 
Alarm 
Emergency 
stop 
Optical 
communication 
Emergency 
stop
 
Alarm 
Contactor shutoff 
command