Mitsumi electronic IB-1500875(ENG)-E ユーザーズマニュアル

ページ / 352
MDS-D/DH Series Specifications Manual
4-4 Drive unit
4 - 29
<For separated arrangement of drive units >
Arranging drive units in the horizontal as much as possible is recommended. Thus, if the drive units 
must be arranged in the vertical, or if the drive units must be separated by more than 30mm, arrange 
them with the DC connection length of 500mm or less.
1. D: For MDS-D-V1-320W, MDS-D-SP-240 to 640, the separated wiring is not available.
DH: For MDS-DH-V1-160W to 200, MDS-DH-SP-160 to 480, the separated wiring is not available.
2. If the drive units are separated by more than 30mm, twist the wires used for the DC connection or 
bundle them with a fixing band in order to prevent two wires from being separated.
3. Failure to observe the above arrangement could damage the units.
 
Fixing band
Twist
1mm
1mm
500mm or less
CAUTION