12. SETTINGS
12.1. Setting Item Summaries
Setting Item
Description
Remote Controller Menu Display (Hold down the Menu key for 2 seconds or more.)
Group
1. Setting
Two or more cascade-connected Digital Recorders can be assigned to a group. 
It is also possible to restrict access to operation of the Remote Controllers in each group.
Expansion
Cannot be used. 
Abbreviation
1. Setting
Operations and functions can be programmed into a function key (F1-F4) and a number (1-508).
Focus Speed
Lens speed when using the Focus key can be adjusted in 4 steps.
2. Transfer
Transfers data to copy already programmed group settings to two or more Remote Controllers
via the C-RF1000 Interface Unit.
3. Erase
Deletes all group settings at a time.
Hold
1. Key
Permits the current screen to be held or switched to an alarm screen by key operation when 
alarm is activated.
2. Always
Continues to retain the screen displayed before alarm activation without switching when alarm
is activated.
Buzzer
The buzzer tone can be set to ON or OFF.
Key Operation Tone
The key operation tone can be set to ON or OFF.
I/O Speed
Sets the transfer rate of data from the control output terminal. 
DVR Check
Confirms whether or not the Digital Recorder is connected to the Remote Controller.
2. Transfer
Transfers data to copy already programmed abbreviation settings to two or more Remote 
Controllers via the C-RF1000 Interface Unit.
3. Erase
Deletes all abbreviation settings at a time.
Password
1. Operation Level 1
Permits access to all function operations. Menus can be displayed, settings can be performed,
and data can bearchived to a USB flash drive or DVD.
Monitor Lock
Multiple Remote Controllers can be individually set to enable ordisable remote operation 
of the Digital Recorder's connected monitor.
Language
1. English   
2. French
Selects the language to be displayed on the LCD screen.
Initial Status
Returns settings to default conditions.
Camera Protocol
Selecting the Camera protocol converts the data programmed into F1 - F4 keys and 
abbreviation number settings into the data for the selected protocol.
2. Operation Level 2
Access is restricted to live mode and playback mode operations, camera operations, and alarm 
reset. Menus cannot be displayed, settings cannot be changed nor can data be archived to the 
USB flash drive or DVD.
3. Operation Level 3
Permits only live image screen viewing. 
4. Log-out time. 
The interval from log-in to log-out can be set. If no operations areperformed for a pre-set period 
of time after log-in, the systemautomatically logs out, moving to the lowest set operation level.
5. Priority recording 
    operator Level 3
Either “Valid” (ON) or “Invalid” (OFF) can be selected for authorization of access to the 
Priority Recording key.