9-3-1    Program Version Number   
                7-segment display reveals program version number. 
 
 
9-3-2    7-segment Display Testing 
                7-segment display reveals 
“     ~   
” and “
.
”. 
 
 
9-3-3    Keypad & Calibration Switch Testing 
                Adjust calibration switch to 
“ON”, and press any key, the corresponding bit will be 
changed from
   
 
 
9-3-4    AD Conversion Value   
                7-segment display reveals the internal value of the present weight. 
 
 
9-3-5    EEPROM Testing 
                Displaying 
 
 
 
  represents in normal condition.   
Displaying 
 
 
  represents in extraordinary condition. 
 
 
9-3-6    RTC Time & Date Testing 
                Press          key to enter the testing mode, and the screen will display date XX.XX.XX. 
Example: 
“05.11.03” represents 3rd of November, 2005. 
                Press          key again to display time XX.XX.XX.                                                       
Example: 
“09.45.50” represents 9 o’clock, 45 minute and 50 seconds. 
 
 
9-3-7    RS-232 Serial Output Interface Testing ( OP-01 ) 
                (1) Short the 2
nd
 pin and 3
rd
 pin of the SER. OUT. D-SUB 9pin socket.     
 
                   
     
Displaying 
 
 
 
  represents in normal condition.   
Displaying 
 
 
  represents in breakdown condition. 
 
                (2) If connected with a computer (protocol must be corresponding), the screen will 
display 
    ~   
, which means RS-232 output is in normal condition. 
 
                   
       
 
 
ENTER 
 
 