Mounting
The transformer can be mounted in one of three ways:
— foot mounting.
— plate mounting.
— mounting through outlet box knockout hole.
Foot Mounting
1. Mount the transformer using screws (not supplied) 
through the four 3/16 in. x 3/8 in. holes in the 
mounting feet. 
2. Make line voltage primary connections within an 
approved enclosure. See Fig. 1. 
3. Discard the mounting plate.
Fig. 1. Foot mounting.
Plate Mounting
MOUNTING PLATE TO TRANSFORMER
Mount the plate to the transformer in either of two 
positions (see Fig. 2):
• at clamp on primary end bell.
• at laminations.
Fig. 2. Mounting plate to transformer in either 
of two positions.
MOUNTING PLATE AT CLAMP ON PRIMARY END BELL
1. Turn the screw on the clamp almost all the way out.
2. Hold the mounting plate with the keyhole slots up 
and the raised portion of the large center knockout 
away from you.
3. From the back, thread the primary leadwires 
through the round center hole in the plate.
4. Fit the clamp and screw through the round hole.
5. While holding the plate in place, tighten the 
setscrew securely against the rim of the hole. 
See Fig. 3. Avoid damaging the leadwires with the 
screwdriver.
USE SCREWS OR 
BOLTS THROUGH
SLOTS (4) IN
MOUNTING FEET
SCREW TERMINALS 
FOR SECONDARY 
CONNECTIONS
MOUNTING 
FOOT (2)
LEADWIRES 
FOR PRIMARY 
CONNECTIONS
M9161
PLATE MOUNTED AT CLAMP ON  PRIMARY END BELL
MOUNTING 
PLATE
MOUNTING PLATE
PLATE MOUNTED AT THE LAMINATIONS
M9162
END
BELL
CLAMP SCREW 
AND CLAMP
RAISED PORTION OF 
LARGE CENTER KNOCKOUT
LEADWIRES 
FOR PRIMARY 
CONNECTIONS
LEADWIRES 
FOR PRIMARY 
CONNECTIONS
MOUNTING
 SCREW
SCREW 
TERMINALS FOR
SECONDARY
CONNECTIONS
SCREW 
TERMINALS FOR
SECONDARY
CONNECTIONS
MOUNTING FEET ON "A" MODELS ONLY.
1
1
1