SMART Technologies 8070i-G4-SMP ユーザーズマニュアル

ページ / 126
A P P E N D I X B
Remotely managing your interactive flat panel
92
smarttech.com/kb/170446
Command
Possible values
Response
Standby
mode
set displaymode [Value]
l
=DYNAMIC
l
=STANDARD
l
=sRGB
l
=CINEMA
l
=SPORT
l
=GAME
l
=USER
l
=AMBIENT
displaymode=[Value]
No
set saturation [Value]
l
[Incremental value]
l
[Incremental value]
l
=0–100
saturation=[Value]
No
set sharpness [Value]
l
[Incremental value]
l
[Incremental value]
l
=0–100
sharpness=[Value]
No
set tint [Value]
l
[Incremental value]
l
[Incremental value]
l
=0–100
tint=[Value]
No
Audio control
Use the following commands to identify audio control settings.
Command
Response
Possible values
Standby
mode
get audioinput
audioinput=[Value]
l
IN1
l
IN2
l
IN3
l
USB
l
HDMI
l
DPORT
l
HDMI3/PC_ANALOG
l
HDMI3/PC_DIGITAL
No
get balance
balance=[Value]
0–100
No
get bass
bass=[Value]
0–100
No
get hdmi3/pc_lineout
hdmi3/pc_lineout=[Value]
l
fixed
l
variable
No
get leftspeaker
leftspeaker=[Value]
l
on
l
off
No
get lineout
lineout=[Value]
l
fixed
l
variable
No
get mute
mute=[Value]
l
on
l
off
No
get rightspeaker
rightspeaker=[Value]
l
on
l
off
No
get treble
treble=[Value]
0–100
No
get volume
volume=[Value]
0–100