12  MAINTENANCE & TROUBLESHOOTING 
 
12-6 
Routine and Business 
priorities only.) 
EPFS error 
No position data from 
navigator for one minute. 
Press the [CANCEL] key to silence the 
alarm. Check the navigator. If it is 
malfunctioning, manually enter position.
Incoming 
Incoming DSC call 
Message is automatically cleared when 
DSC signal has gone. 
No position data 
You attempted to enter 
position automatically when 
there is no position data. 
Check the navigator.   
No response: RT 
Radiotelephone not powered 
or has been disconnected. 
Check radiotelephone. 
Oven cold. Tx not 
ready; wait 
Oven too cold; cannot 
transmit. 
Wait until the oven becomes sufficiently 
warm. 
Printer not ready 
Automatic printed has been 
selected; however, printer is 
not powered or has been 
disconnected. 
Check printer. 
Trouble: Oven not 
ready 
Oven not ready; cannot 
transmit. 
Wait until the oven is ready. 
TRX PLL UNLOCK 
TRX PLL unlock. 
Transmission is stopped. 
Check if the reference oscillator is 
working and the coaxial cable is tightly 
connected. 
TUNE error 
Tuning failed for DSC or 
NBDP. Transmission (except 
distress) is stopped. 
Try to tune again. 
Warning: Update 
position 
Position data is older by the 
amount of time preset on the 
Alarm menu.   
Press the [CANCEL] key to silence 
alarm. Reenter position on the Position 
menu. 
Watchdog error. 
Please Power OFF 
Internal error (such as CPU 
trouble) detected. 
Accompanied with alarm, 
same type as for distress. 
Turn the power off and on to erase the 
message. Have a qualified technician 
check the set. 
WR1 PLL UNLOCK 
WR2 PLL UNLOCK 
WR1, WR2 PLL unlock. 
Transmission is stopped. 
Check if the reference oscillator is 
working and the coaxial cable is tightly 
connected. 