Four Slot Spare Battery Charger
This section describes how to use the Four Slot Spare Battery Charger to charge up to four wearable terminal
spare batteries.
spare batteries.
Figure 3-3
Four Slot Spare Battery Charger
Spare Battery Charging with the Four Slot Spare Battery Charger
Insert the battery into a spare battery charging slot and gently press down on the battery to ensure proper
contact.
contact.
Battery Charging Indicators
An amber LED is provided on each battery charging well. See
for charging status indications.The
standard capacity battery usually charges in less than four hours.
Spare Battery Charging LEDs (4)
Spare Battery
Spare Battery Charging Well (4)
CAUTION
Use only a Symbol approved power supply output rated 12 VDC and minimum 3.3 A. Use of an
alternative power supply will void the product warranty and may cause product damage. See
alternative power supply will void the product warranty and may cause product damage. See
for the power supply regulatory compliance statement.
Table 3-2
Spare Battery LED Charging Indicators
LED
Indication
Off
No spare battery in slot; spare battery not placed correctly; cradle is not powered.
Fast Blinking Amber
Charging error:
•
Temperature is too low or too high.
•
Charging has gone on too long without completing (typically eight hours).
Slow Blinking Amber
Spare battery is charging.
Solid Amber