Troubleshooting
Wearable Terminal
Table 4-1    
Troubleshooting the Wearable Terminal
Problem
Cause
Solution
Wearable terminal 
does not turn on.
Lithium-ion battery 
not charged.
Charge or replace the lithium-ion battery in the wearable 
terminal.
Lithium-ion battery 
not installed 
properly.
Ensure battery is installed properly. See 
System crash.
Perform a warm boot. If the wearable terminal still does not 
turn on, perform a cold boot. See 
Rechargeable 
lithium-ion battery did 
not charge.
Battery failed. 
Replace battery. If the wearable terminal still does not operate, 
try a warm boot, then a cold boot. See 
Wearable terminal 
removed from 
cradle while battery 
was charging.
Insert wearable terminal in cradle and begin charging. The 
lithium-ion battery requires less than four hours to recharge 
fully.
Ambient 
temperature of the 
cradle is too warm 
or too cold.
Move the cradle to an area where the ambient temperature is 
between 0 °C and 40 °C (32 °F and 104 °F).
Cannot see 
characters on display.
Wearable terminal 
not powered on.
Press the Power button.
During data 
communication, no 
data was transmitted, 
or transmitted data 
was incomplete.
Wearable terminal 
removed from 
cradle or unplugged 
from host computer 
during 
communication.
Replace the wearable terminal in the cradle, or reattach the 
Synchronization cable and re-transmit.
Incorrect cable 
configuration.
See the System Administrator.
Communication 
software was 
incorrectly installed 
or configured.
Perform setup. Refer to the WT4090 Integrator Guide for 
details.
Ensure that Microsoft ActiveSync 4.1 or greater is installed on 
the host computer.