BASIC LEVEL CHECKS AND SELF TESTS:  Customer Care
20
68P80401P05
CHAPTER 5
BASIC LEVEL CHECKS AND SELF TESTS
Before you perform basic troubleshooting and self tests on an i580 unit, determine if any special 
conditions could affect testing and check the units for defective parts.
There are five categories of basic tests:
Preventive maintenance
Mechanical/electrical checks
Self tests
Technician tests 
Test procedures are listed in the order in which they should be implemented. Each test contains a 
description of what it does and the approximate time needed to perform it. For your convenience, a 
checklist is included that can be used to ensure that all the necessary tests are conducted.
5.1
Customer Care
It is sometimes helpful to contact your regional Customer Care representative to determine if the 
customer has service or billing issues or is known to be using the unit in a poorly covered area. The 
representative also can inform you if there are system outages or known unit defects.
5.2
Test Conditions
During testing, ensure the following antenna conditions are adhered to. Reset conditions can be 
comparatively difficult to diagnose.
5.2.1
Antenna Condition
For intermittent or no transmit problems, ensure the antenna stays fully extended or fully collapsed 
at all times, never partially extended. If the antenna is loose or collapses halfway down, the unit can 
lose up to 20 dB of radiated power.
5.2.2
Reset Condition
A reset condition can be the most difficult failure to duplicate because a reset can be caused by 
software, hardware, system, accessory, and coverage problems. A severe hardware failure usually 
can be detected immediately.