MECHANICAL PARTS REWORK AND REPAIR:  Mechanical Parts Rework Procedure
84
68P80401P05
9.5.13 D401 through D412 (LED)
Orientation
 
NOTE: Use Liquid Flux Indium-Indalloy NC771 ONLY. Use flux sparingly.
NOTE: Always protect switches from heat and Flux intrusion to avoid component malfunction.
Top 330ºC - No Bottom Heat
N-Q07
OK Industries   151/min
Pace                 6/7
“I” over nearby SW during Removal Procedure.
“I” over nearby SW & “A” over LED during 
Installation Procedure.