Motorola G24 ユーザーズマニュアル

ページ / 642
GPRS/EDGE
3-414
 AT Commands Reference Manual
December  31, 2007
OK
AT+MSDNS?
+MSDNS: 1,"192.118.9.177","192.118.11.77"
+MSDNS: 2,"192.118.9.177","192.118.11.77"
+MSDNS: 3,"192.118.9.177","192.118.11.77"
+MSDNS: 4,"192.118.9.177","192.118.11.77"
+MSDNS: 5,"192.118.9.177","192.118.11.77"
OK
AT+MIPCALL=0
OK
NO CARRIER
+MIPCALL: 0
AT+MSDNS?                       // read when MIPCALL is disconnected
+MSDNS: 1,"0.0.0.0","0.0.0.0"
+MSDNS: 2,"0.0.0.0","0.0.0.0"
+MSDNS: 3,"0.0.0.0","0.0.0.0"
+MSDNS: 4,"0.0.0.0","0.0.0.0"
+MSDNS: 5,"0.0.0.0","0.0.0.0"
OK
+MIPCSC, Motorola Control Secured Connection
This AT command is used to configure the SSL feature behavior in case of non - fatal alerts. For 
each non - fatal alert, user should decide if the secure connection should be closed automatically 
or not.
Command Type
Syntax
Response/Action
Remarks
Set
AT+MIPCSC=<SocketID>,<n>
OK
or:
+CME ERROR: <err>
The Set 
command is used 
for setting the 
SSL connection 
behavior in case 
of non - fatal 
alerts.
Read
AT+MIPCSC?
+ MIPCSC:  1,<n>
+ MIPCSC:  2,<n>
+ MIPCSC:  3,<n>
+ MIPCSC:  4,<n>
OK
The Read 
command 
returns the 
current SSL 
connection 
behavior in case 
of non - fatal 
alerts.
Test
AT+MIPCSC=?
+ MIPCSC:  
(1-4),(0- 2047)
OK
The Test 
command 
returns the 
possible range of 
values.