Omega OSP SERIES ユーザーズマニュアル
7
1.1
Instrument codes
To Order
Model No.
Temperature
Range
Spectral
Response
Target Spot Size
@ Distance **
D/S Optical Ratio
OSP500-(*)
–30 °C to +930 °C
-20°F to +1706°F
8 to 14
µ
m
10mm @ 600mm
0.39 @ 24”
60:1
OSP800-(*)
–30 °C to +930 °C
-20°F to +1610°F
8 to 14
µ
m
10mm @ 600mm
0.39 @ 24”
60:1
OSP1000-(*)
–30 °C to +1000 °C
-20°F to +1830°F
8 to 14
µ
m
10mm @ 1000mm
0.39 @ 39.4”
100:1
OSP1300-(*)
+300 °C to +1300 °C
+570°F to 2370°F
1.6
µ
m
6mm @ 1000mm
0.236 @ 39.4”
167:1
OSP1600-(*)
+600 °C to +1600 °C
+1120°F to 2900°F
1
µ
m
5mm @ 1000mm
0.20 @ 39.4”
200:1
OSP2000-(*)
+600 °C to +2000 °C
+1120°F to +3630°F
1
µ
m
5mm @ 1000mm
0.20 @ 39.4”
200:1
* Insert suffix codes B and C and D from options chart above
** See Target spot size diagram
** See Target spot size diagram
Note
: all accessories and options must be specified at time of order.
Each Pyrometer supplied with
: Alkaline battery, laser, operators manual, and calibration report
Options
Suffix Code
Suffix Code
Description
OSP500
OSP800
OSP1000
OSP1300
OSP1600
OSP2000
-B0
Alkaline battery
std
std
std
std
std
std
-B1
Rechargeable Battery
Opt
Opt
Opt
Opt
Opt
Opt
-C1
Single Laser
Std
No
No
No
No
No
-C2
Twin crossed Lasers
No
Std
Std
Std
Std
Std
-C3
Twin normal Lasers
No
Std
Std
std
Std
Std
-C4
Single Laser with Circle
Std
No
No
No
No
No
-D1
Vinyl Case
Std
Std
No
std
Std
No
-D2
Aluminum Case
Opt
Opt
Std
Opt
Opt
Std
-D3
Memory+Software+RS232 Cable
Opt
Opt
Std
Opt
Opt
Std
-D6
Sighting telescope
No
No
Opt
Opt
Opt
Opt
-D7
Red Point
No
No
No
Opt
Opt
Opt
-D8
Alarms
Std
Std
Std
std
std
Std
-D9
Analog Output
Opt
Std
std
std
std
Std
-DA
Aux Input for Tc K & S
Opt
std
std
std
std
Std
Report of Calibration
std
std
std
std
std
Std
No = Not available
Std = Standard at no extra cost
Single laser
: General application, target center
Single laser with circle
: General application, target center plus target dimension with circle (short distance)
Twin crossed lasers
: General application, target dimension
Twin normal lasers
(parallel): Long distance application over 5m (16’)
Red Point
: High temperature over 1250°C 1x
Sighting Telescope
: High temperature over 1250°C 2x tele
Software
(D3): Includes memory up to 500 values. You can divide them by Tag (20 different). Each value includes
temperature value and date&time (built in real time clock). Tag name with 7 characters on instrument
display. Datalogging manual or automatic with sampling time from 1 to 999 sec. Windows 95 software to
download data to PC and cable. You can view, save, print, export to Excel and graph data.
display. Datalogging manual or automatic with sampling time from 1 to 999 sec. Windows 95 software to
download data to PC and cable. You can view, save, print, export to Excel and graph data.
U.S. and international Patents and Patents Pending.