6. APPLICATION FUNCTIONS 
 
(3) Cautions for use of absolute position detection system 
In the case of the following (a) to (f), the absolute position erased signal (ABSE) is turned on and the 
absolute position data of the home position return option 2 (parameter No.0241) is changed to 0 (invalid). 
Furthermore, the servo is not yet finished with home position return, and the home position return request 
(ZREQ) turns on. Therefore when performing automatic operation, execute home position return again. (In 
cases other than (a))  
 
POINT 
 
If the absolute position erased signal (ABSE) is turned on, re-execute home 
position return and read the home position multiple revolution data and home 
position within one-revolution position. 
 
 
(a) When parameters related to the home position return (parameter No.0240, 0246 to 0249, and 024D to 
024F), electronic gear (parameter No.020A to 020D), and rotation direction selection (parameter 
No.110D) are changed. (For software version A5 or later, absolute position erased signal (ABSE) does 
not turn ON when parameter No.0240 is changed.) 
 
(b) If "absolute position erased " (servo alarm 25) or "absolute position counter warning" (servo alarm E3) 
occurs, note that these alarms will be cleared by servo amplifier power OFF/ON. 
 
(c) Parameter error (servo alarm 37) occurs. 
 
(d) The setting value for "home position multiple revolution data" (parameter No.024D) or "home position 
within 1 revolution position" (parameter No.024E, 024F) is incorrect and overflow in calculating absolute 
position restoration occurs. 
 
(e) "Tandem drive synchronous valid width error" (operation alarm No. 54, detail 01) or "Tandem drive 
synchronous alignment error" (operation alarm 58, detail 01) occurs. 
 
(f) Electronic gear setting error (system error E500) occurs. This error causes a forced stop status to 
prevent operation.  Reexamine the setting of an electronic gear and start the system again.  
 
 
POINT 
 
The position after startup (restoration of absolute position) is determined using the following. 
 
Restoration absolute position (pulse)    (within 1 revolution position at system startup  
 home position within 1 revolution position) 
 (multiple revolution data at system startup  
 home position multiple revolution data) 
 number of encoder pulses per revolution 
 
Restoration absolute position (command unit)   restoration absolute position (pulse)  
 reciprocal of number of electronic gears (Note)  
 home position coordinate 
 
Note. reciprocal of number of electronic gears   electronic gear denominator (CDV)/electronic gear numerator (CMX)